Концентрация цитрата натрия влияет на коагуляционную пробу

By LabMedica International staff writers
Posted on 03 Oct 2018
Несмотря на высокую степень стандартизации, коагуляционные пробы во многом зависят от преаналитических факторов. More...
Помимо артефактов, которые возникают при взятии и транспортировке крови, используемый антикоагулянт in vitro потенциально влияет на результат теста свертывания крови.

Обычно соотношение крови к цитрату натрия 9:1 используется с буферным диапазоном от 3,2 до 3,8%. 3,2%-ный буферный раствор цитрата натрия связывает меньше добавленного в анализ кальция, чем 3,8%-ный буферный раствор цитрата натрия, поэтому время свертывания, как правило, у 3,2%-ого буферного раствора цитрата натрия короче, чем у 3,8%-ого. Точные данные отсутствуют, но в настоящее время широко используется 3,2%-ный буферный раствор цитрата натрия.

Ученые из Медицинской лаборатории Венского медицинского университета (Medical University of Vienna; Вена, Австрия) провели проспективное обсервационное исследование с участием 76 добровольцев. Были оценены различия, связанные с концентрацией цитрата натрия. Для обеих концентраций буферного раствора были установлены референтные диапазоны. При использовании аналогичных калибровочных параметров были последовательно проанализированы образцы 3,2%-ого и 3,8%-ого буферных растворов цитрата натрия. Комбинации реагентов-анализаторов были выбраны с точки зрения точности и достоверности измерений, надежности анализов и практичности на этапе ввода параметров в лаборатории.

Чувствительный к волчанке реагент активированного частичного тромбопластинового времени (activated partial thromboplastin time lupus-sensitive reagent - aPTT-LA) для контрольного анализа волчаночного антикоагулянта (lupus anticoagulant - LAC) был проанализирован с использованием плазмы с реагентом, содержащим фосфатидилэтаноламин, или без него. Контрольный анализ волчаночного антикоагулянта считался положительным, когда различие между временем свертывания aPTT-LA было больше восьми секунд или соотношение между чистым временем свертывания под воздействием разбавленного яда гадюки Рассела (diluted Russell viper venom time - dRVVT) и dRVVT Confirm (dRVVT Ratio, Staclot DRVV Screen/Staclot DRVV Confirm) было больше 1,25.

Команда обнаружила, что большинство оцениваемых параметров показало хорошую сопоставимость между цитратными образцами, взятыми с 3,2%-м и 3,8%-м буферным раствором тринатриевого цитрата. Эллагиновая кислота, содержащая реагент активированного частичного тромбопластинового времени (aPTT-FS), указывала системную и пропорциональную разницу между обеими концентрациями буферных растворов, что приводило к изменению его референтных диапазонов. Кроме того, контрольный анализ на волчаночный антикоагулянт (Staclot LA) показал лишь умеренную корреляцию с пропорциональным отклонением между концентрациями цитрата. Статистически значимое различие было обнаружено в контрольном анализе с разбавленным ядом гадюки Рассела, факторах свертывания V и VIII, а также незначительная клиническая значимость была обнаружена в активности протеина С.

Авторы пришли к выводу, что изменение 3,2%-ого и 3,8%-ого буферных растворов цитрата натрия в специализированных тестах на коагуляцию в данных условиях имело ограниченную значимость. В качестве исключения концентрация цитрата оказала значительное влияние на разницу aPTT-FS и aPTT-LA. Эти данные демонстрируют сопоставимость данных, оцененных с диапазонами концентрации цитрата. Исследование было опубликовано в августе 2018 года в журнале "Архивы патологии и лабораторной медицины" (Archives of Pathology & Laboratory Medicine).


Ссылки по теме:
Венский медицинский университет



Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Neonatal Heel Incision Device
Tenderfoot
New
Gastrointestinal Panel
Xpert® GI Panel
LAIR2 Antibody Pair Set
LAIR2 Antibody Pair [Biotin]
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: LVOne uses blood-based biomarkers to detect stroke and identify large vessel occlusion before hospital arrival, providing objective results earlier than traditional assessments. (Photo courtesy of UpFront Diagnostics)

First-of-Its-Kind Rapid Blood Test Gains CE Mark to Support Prehospital Stroke Triage

Rapid stroke identification before hospital arrival is critical because treatment efficacy declines with every minute of delay. However, definitive assessment typically requires hospital-based imaging,... Read more

Molecular Diagnostics

view channel
Image Credit: iStock

Mpox Analysis Reveals Substantial Suspected False Positives Associated with Contamination

Reliable confirmation of mpox can be difficult where multiple rash-causing illnesses co-circulate and laboratory capacity is limited. Although PCR is central to case detection, contamination during specimen... Read more

Immunology

view channel
Image: Aptiva utilizes particle-based multi-analyte technology (PMAT) (Photo courtesy of Werfen)

Werfen Expands Automated APS Testing with FDA-Cleared and CE-Marked IgA Reagent

Antiphospholipid syndrome (APS) is an autoimmune disorder associated with thrombosis and pregnancy complications, but its symptoms can overlap with those of other conditions, complicating diagnosis.... Read more

Microbiology

view channel
Image: Ebola remains a rapidly evolving public health threat with high mortality, underscoring the need for timely diagnosis and decentralized testing closer to patients (Image Credit: Adobe Stock)

Collaboration Targets Blood-Based Ebola Detection Outside Central Laboratories

Co-Diagnostics, Inc. (Salt Lake City, UT, USA) and ReadyGo Diagnostics Ltd. (Bath, UK) have initiated a collaboration to evaluate ReadyGo’s GoCollect with the Co-Dx PCR platform for blood-based molecular... Read more

Pathology

view channel
Image: A new study demonstrates that vascular features in colorectal tumors could serve as prognostic biomarkers of disease outcome. (Image Credit: iStock)

Tumor Blood Vessel Features May Help Predict Colorectal Cancer Survival

Colorectal cancer outcomes vary widely, and tumor biology remains a key determinant of prognosis. Because neoplasms depend on a vascular supply, differences in intratumoral vessels may influence survival.... Read more

Technology

view channel
Image: ADLM recommends that emerging AI tools follow the same professional oversight, quality, validation, and monitoring standards as traditional clinical testing within CLIA’s existing framework (Image Credit: Adobe Stock)

ADLM Calls for CLIA Updates to Support Safe AI Use in Laboratory Medicine

Clinical laboratories increasingly use artificial intelligence to verify, interpret, and report results, but safeguards under the Clinical Laboratory Improvement Amendments (CLIA) were designed in 1992.... Read more

Industry

view channel
Image: Central to the collaboration is the Enhanced Liver Fibrosis (ELF) test, a noninvasive blood test authorized in the U.S. to assess disease progression risk in patients with advanced fibrosis due to MASH and support patient management decisions. (Photo courtesy of Siemens Healthineers)

Siemens Healthineers and Novo Collaborate to Expand Access to Noninvasive Liver Testing

Metabolic dysfunction‑associated steatotic liver disease (MASLD) and its progressive form, metabolic dysfunction‑associated steatohepatitis (MASH), affect millions and are linked to obesity, type 2 diabetes,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.