Plasma Amyloid-β 42/40 Assays Compared in Alzheimer Disease

By LabMedica International staff writers
Posted on 14 Oct 2021
Blood-based tests for brain amyloid-β (Aβ) pathology are needed for widespread implementation of Alzheimer disease (AD) biomarkers in clinical care and to facilitate patient screening and monitoring of treatment responses in clinical trials.

Reliable measurements of Aβ in blood proved challenging until the development of advanced mass spectrometry and immunodetection methods. More...
Recent articles have suggested that Aβ42/40 quantified using ultrasensitive and fully automated immunoassay platforms could predict Aβ-PET status (especially when combined with APOE genotype) with accuracy approaching that of MS-based Aβ42/40 measures.

An international team led by Clinical Neuroscientists at Lund University (Lund, Sweden) compared the performance of plasma Aβ42/40 measured using eight different Aβ assays when detecting abnormal brain Aβ status in patients with early AD. The study included 182 cognitively unimpaired participants and 104 patients with mild cognitive impairment who were enrolled at three different hospitals in Sweden and underwent Aβ positron emission tomography (PET) imaging and cerebrospinal fluid (CSF) and plasma collection from 2010 to 2014.

Plasma Aβ42/40 was measured using an immunoprecipitation-coupled mass spectrometry developed at Washington University School of Medicine (IP-MS-WashU, St Louis, MO, USA), antibody-free liquid chromatography MS developed by Araclon (LC-MS-Arc, Zaragoza, Spain), and diverse immunoassays. Plasma Aβ42/40 was also measured using an IP-MS–based method from Shimadzu (Kyoto, Japan) in 200 participants (IP-MS-Shim) and an IP-MS–based method from the University of Gothenburg (IP-MS-UGOT, Gothenburg, Sweden) and another immunoassay, the N4PE Simoa immunoassay (IA-Quan, Quanterix Billerica, MA, USA) among 227 participants.

When the team identified participants with abnormal CSF Aβ42/40 in the whole cohort, plasma IP-MS-WashU Aβ42/40 showed significantly higher accuracy than LC-MS-Arc Aβ42/40, and some immunoassays. Plasma IP-MS-WashU Aβ42/40 performed significantly better than IP-MS-UGOT Aβ42/40 and IA-Quan Aβ42/40, while there was no difference in the AUCs between IP-MS-WashU Aβ42/40 and IP-MS-Shim Aβ42/40) in the two sub-cohorts where these biomarkers were available. Plasma IPMS-WashU Aβ42/40 and IP-MS-Shim Aβ42/40 showed highest coefficients for correlations with CSF Aβ42/40.

The authors concluded that the results from two independent cohorts indicate that certain MS-based methods performed better than most of the immunoassays for plasma Aβ42/40 when detecting brain Aβ pathology. The study was published on September 20, 2021 in the journal JAMA Neurology.

Related Links:
Lund University
Washington University School of Medicine
Araclon
University of Gothenburg
Quanterix



Gold Member
Cardiovascular Risk Test
Metabolic Syndrome Array I & II
Collection and Transport System
PurSafe Plus®
Gel Cards
DG Gel Cards
8-Channel Pipette
SAPPHIRE 20–300 µL
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: New evidence shows viscoelastic testing can improve assessment of blood clotting during postpartum hemorrhage (Photo courtesy of 123RF)

Viscoelastic Testing Could Improve Treatment of Maternal Hemorrhage

Postpartum hemorrhage, severe bleeding after childbirth, remains one of the leading causes of maternal mortality worldwide, yet many of these deaths are preventable. Standard care can be hindered by delays... Read more

Immunology

view channel
Image: When assessing the same lung biopsy sample, research shows that only 18% of pathologists will agree on a TCMR diagnosis (Photo courtesy of Thermo Fisher)

Molecular Microscope Diagnostic System Assesses Lung Transplant Rejection

Lung transplant recipients face a significant risk of rejection and often require routine biopsies to monitor graft health, yet assessing the same biopsy sample can be highly inconsistent among pathologists.... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.