Immunochromatographic Test Evaluated to Diagnose Schistosomiasis

By LabMedica International staff writers
Posted on 02 Feb 2016
Print article
Image: The circulating cathodic antigen immunochromatographic test of two patient’s urine for Schistosoma mansoni (Photo courtesy of Saarland University).
Image: The circulating cathodic antigen immunochromatographic test of two patient’s urine for Schistosoma mansoni (Photo courtesy of Saarland University).
The Kato-Katz (KK) stool smear is the standard test for the diagnosis of Schistosoma mansoni infection but suffers from low sensitivity when infections intensities are moderate to low and therefore, misdiagnosed individuals remain untreated and contribute to the disease transmission.

As an alternative, the urine-based diagnosis of schistosomiasis mansoni via the circulating cathodic antigen immuno-chromatographic test (CCA-ICT) has been extensively evaluated in Africa with the conclusion that it may replace the KK test in areas where the prevalence is moderate or high.

Scientists at the University Vale do Rio Doce (Governador Valadares, Brazil) and their colleagues measured the performance of the CCA-ICT in a sample study population composed of residents from non-endemic and endemic areas for schistosomiasis in two municipalities of Minas Gerais state (Brazil). Volunteers were classified into three infection status groups based on duplicate Kato-Katz thick smears from one stool sample (2KK test): 41 negative individuals from non-endemic areas, 41 negative individuals from endemic areas and 48 infected individuals from endemic areas.

The rapid immuno-chromatographic test used was the commercially available Bilharzia RDT (Rapid Medical Diagnostics; Pretoria, Republic of South Africa), which measures a parasite-derived “circulating cathodic antigen (CCA)” in the urine of patients infected with S. mansoni. Infection status was also determined by the CCA-ICT and infection exposure by antibody enzyme-linked immunosorbent assay (ELISA) to S. mansoni soluble egg antigen (SEA) and soluble (adult) worm antigen preparation (SWAP).

The investigators found that sensitivity and specificity were influenced by whether the trace score visually adjudicated in the CCA-ICT was characterized as positive or negative for S. mansoni infection. When the trace score was interpreted as a positive rather than as a negative result, the specificity decreased from 97.6% to 78.0% whereas sensitivity increased from 68.7% to 85.4%. A significantly positive correlation between the CCA-ICT scores and egg counts was identified. Considering 2KK as reference test, the discriminating power of the CCA-ICT was greater than the SEA-ELISA and SWAP-ELISA.

The authors concluded that the performance of the CCA-ICT in the Brazilian communities endemic for schistosomiasis mansoni support those from Africa in areas with greater infection prevalence and intensities, the CCA-ICT may be useful as a tool to indicate community-based preventative chemotherapy without individual diagnosis. However, because of the Brazilian Ministry of Health’s recommendation for individual diagnosis in areas where prevalence is less than 15%, in those areas in which infection intensities are likely to be lowest, the CCA-ICT lacks the sensitivity to be used as standalone diagnostic tool. The study was published on January 11, 2016, in the journal Public Library of Science Neglected Tropical Diseases.

Related Links:

University Vale do Rio Doce 
Rapid Medical Diagnostics


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Specimen Collection & Transport
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Reagent Reservoirs
Reagent Reservoirs

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: The study showed the blood-based cancer screening test detects 83% of people with colorectal cancer with specificity of 90% (Photo courtesy of Guardant Health)

Blood Test Shows 83% Accuracy for Detecting Colorectal Cancer

Colorectal cancer is the second biggest cause of cancer deaths among adults in the U.S., with forecasts suggesting 53,010 people might die from it in 2024. While fewer older adults are dying from this... Read more

Hematology

view channel
Image: The Gazelle Hb Variant Test (Photo courtesy of Hemex Health)

First Affordable and Rapid Test for Beta Thalassemia Demonstrates 99% Diagnostic Accuracy

Hemoglobin disorders rank as some of the most prevalent monogenic diseases globally. Among various hemoglobin disorders, beta thalassemia, a hereditary blood disorder, affects about 1.5% of the world's... Read more

Industry

view channel
Image: These new assays are being developed for use on the recently introduced DxI 9000 Immunoassay Analyzer (Photo courtesy of Beckman Coulter)

Beckman Coulter and Fujirebio Expand Partnership on Neurodegenerative Disease Diagnostics

Beckman Coulter Diagnostics (Brea, CA, USA) and Fujirebio Diagnostics (Tokyo, Japan) have expanded their partnership focused on the development, manufacturing and clinical adoption of neurodegenerative... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.