We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Rapid Ebola Test Validated in Field Trials

By LabMedica International staff writers
Posted on 15 Jul 2015
Print article
The ReEBOV Antigen Rapid Test for Ebola viral infection
The ReEBOV Antigen Rapid Test for Ebola viral infection (Photo courtesy of CORGENIX UK LTD.)
At present, diagnosis of Ebolavirus disease requires transport of venipuncture blood to field biocontainment laboratories for testing by real-time reverse transcription polymerase chain reaction (RT-PCR), resulting in delays that complicate patient care and infection control efforts.

However, RT-PCR is a slow and complex test that comes with attached risks for the health care workers responsible for the collection, transportation and testing of the blood. The complexity and slow turnaround for this diagnostic have been blamed for delaying success in containing the Ebola epidemic.

An international team led by those at the Boston Children's Hospital (MA. USA) performed a rapid diagnostic test on fingerstick blood samples from 106 individuals with suspected Ebolavirus disease presenting at two clinical centers in Sierra Leone during February 2015. They compared the point-of-care rapid diagnostic test results with clinical real-time RT-PCR results (RealStar Filovirus Screen RT-PCR kit 1·0; altona Diagnostics GmbH; Hamburg, Germany) for venipuncture plasma samples tested in a Public Health England field reference laboratory.

The team also performed the rapid diagnostic ReEBOV Antigen Rapid Test (Corgenix; Broomfield, CO, USA), on whole blood and real-time RT-PCR on plasma, on 284 specimens in the reference laboratory, which were submitted to the laboratory for testing from many clinical sites in Sierra Leone. In point-of-care testing, all 28 patients who tested positive for Ebolavirus disease by RT-PCR were also positive by fingerstick rapid diagnostic test and 71 of 77 patients who tested negative by RT-PCR were also negative by the rapid diagnostic test. In laboratory testing, all 45 specimens that tested positive by RT-PCR were also positive by the rapid diagnostic test, and 214 of 232 specimens that tested negative by RT-PCR were also negative by the rapid diagnostic test.

The authors concluded that the ReEBOV rapid diagnostic test had 100% sensitivity and 92% specificity in both point-of-care and reference laboratory testing in this population. With two independent readers, the test detected all patients who were positive for Ebolavirus by altona real-time RT-PCR; however, this benchmark itself had imperfect sensitivity. The study was published on June 26, 2015, in the journal the Lancet.

Related Links:

Boston Children's Hospital 
altona Diagnostics GmbH
Corgenix 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.