Posted on 09 Jun 2015
Print article
Image: Bone marrow aspiration showing Histoplasma capsulatum (A) and the yeast stained with Periodic Acid Schiff reagent (B) (Photo courtesy of Gareth Gregory and Rose Linda).
Image: Bone marrow aspiration showing Histoplasma capsulatum (A) and the yeast stained with Periodic Acid Schiff reagent (B) (Photo courtesy of Gareth Gregory and Rose Linda).
The rapid identification of four pathogens and the early diagnosis of the four different diseases are of great importance; however some pathogens have a similar size and shape in the Wright‑Giemsa staining of bone marrow smears.

A novel method has been developed to rapidly identify the pathogens Penicillium marneffei, Histoplasma capsulatum, Mucor, and Leishmania donovani in bone marrow smears that can lead to the diseases penicilliosis marneffei, histoplasmosis, mucormycosis, and leishmaniasis, respectively.

Clinical laboratory scientists at Guangxi Medical University (Nanning, China) obtained 55 bone marrow smears (BMS) that were infected. There were 25 invaded by P. marneffei, 10 with H. capsulatum, 3 with Mucor, and 17 infected by L. donovani. The diagnosis of the four diseases was confirmed by pathogen culture. Each BMS was fixed by 95% alcohol for 10 minutes, prior to being washed, dried, stained by 1% periodic acid for 20 minutes and washed and dried once more. Each BMS was then stained by a Schiff reagent for 60 minutes, washed and dried, and subsequently stained by hematoxylin for five minutes, washed and dried. The BMSs were observed using light microscopy. Wright‑Giemsa staining was also performed, following standard protocols.

In the Wright Giemsa staining, the four pathogens were approximately the same size and mainly existed in macrophages. The multiplying P. marneffei had two nuclei, which were on both sides of the fungus, and had light cross walls in the middle. H. capsulatum had a purplish nucleus, which occupied between one third and one half of the spore. The cytoplasm was light blue. Peripheral spores were observed in the form of an empty, bright ring without color, like a capsule.

Generally Mucor were observed to have a long and lightly stained area, which could be confused with the Wright staining of dinuclear P. marneffei. L. donovani exhibited a deep staining kinetoplast near the nucleus. In the Periodic Acid Schiff (PAS) staining, the pathogens of P. marneffei and H. capsulatum were distinct and stained red.

The authors concluded that their staining method was simple and can enable the rapid diagnosis of penicilliosis marneffei, histoplasmosis, mucormycosis and visceral leishmaniasis. Furthermore, the method may have an important role in diag-nosing the four diseases in cases in which it is not possible to conduct pathogen culture and serology tests. The study was published in the May 2015 issue of the journal Experimental and Therapeutic Medicine.

Related Links:

Guangxi Medical University 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The new method could reduce undiagnosed cancer cases in less-developed regions (Photo courtesy of 123RF)

New Method Offers Sustainable Approach to Universal Metabolic Cancer Diagnosis

Globally, more than one billion people suffer from a high rate of missed disease diagnosis, highlighting the urgent need for more precise and affordable diagnostic tools. Such tools are especially crucial... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.