Point-of-Care Blood Test Evaluated for Ebola Virus Disease

By LabMedica International staff writers
Posted on 08 Apr 2015
Print article
Image: Digitally-colorized scanning electron micrograph (SEM) of budding filamentous Ebolavirus particles (Photo courtesy of the US National Institute of Allergy and Infectious Diseases).
Image: Digitally-colorized scanning electron micrograph (SEM) of budding filamentous Ebolavirus particles (Photo courtesy of the US National Institute of Allergy and Infectious Diseases).
Current Ebolavirus disease (EVD) diagnosis relies on reverse transcription-polymerase chain reaction (RT-PCR) technology, requiring skilled laboratory personnel and technical infrastructure.

Lack of laboratory diagnostic capacity has led to diagnostic delays in the current West African EVD outbreak of 2014 and 2015, compromising outbreak control, with an estimated 24,701 cases and over 10,000 deaths.

Scientists at King's College London (UK) and their international colleagues evaluate the diagnostic accuracy of an EVD rapid diagnostic test (RDT) compared with the gold standard Ebola virus (EBOV) RT-PCR in an operational setting for EVD diagnosis of suspected EVD cases admitted to Ebola holding units (EHUs) in the Western Area of Sierra Leone. A total of 138 participants were enrolled and recruited consecutively at study sites, from January 22 to February 16, 2015.

The Defence Science and Technology Laboratory (DSTL; Porton Down, UK) have developed a rapid antigen diagnostic test (RDT) for EVD diagnosis. The DSTL EVD RDT is a bedside lateral flow assay using capillary blood rather than venous blood to detect presence of an undisclosed Ebolavirus antigen. The test can be conducted and interpreted with minimal training and the result is obtained within 20 minutes. A semi-quantitative result is obtained by scoring a test line on color intensity. The EVD RT-PCR testing was performed on venipuncture blood samples with the Altona RealStar Filovirus screen kit for RT-PCR (Altona Diagnostics; Hamburg, Germany).


Fifteen of 131 patients tested positive for EVD by EVD RT-PCR, giving a study EVD prevalence of 11.5%. All EVD cases were identified by a positive RDT with a test line score of six or more, giving a sensitivity of 100% and the corresponding specificity was high at 96.6%. The positive and negative predictive values for the population prevalence were 79.0% and 100%, respectively. The authors concluded that the DSTL EVD RDT is highly sensitive, specific and performs well in an operational setting. A high sensitivity is critical to EVD diagnostic test acceptability.


A highly sensitive screening test such as this would allow high-risk suspected EVD cases to be prioritized for isolation and confirmatory diagnostic testing with RT-PCR, reducing non-EVD admissions in EHUs. If the sensitivity was lower, EVD-positive cases could be inappropriately discharged to inpatient wards, with risks of onward nosocomial transmission. This RDT could be used as a “rule-out” screening test for EVD to improve rapid case identification and resource allocation. The study was published on March 16, 2015, in the journal Eurosurveillance.

Related Links:

King's College London 
Defence Science and Technology Laboratory
Altona Diagnostics


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Liquid biopsy could detect and monitor aggressive small cell lung cancer (Photo courtesy of Shutterstock)

Blood-Based Test Detects and Monitors Aggressive Small Cell Lung Cancer

Small cell lung cancer (SCLC) is a highly aggressive type of cancer known for its ability to metastasize. The behavior of tumors is largely governed by which genes are turned on, or transcribed, irrespective... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.