Effectiveness of Point-of-Care Diagnostics for Schistosomiasis, Reviewed

By LabMedica International staff writers
Posted on 16 Mar 2015
Print article
Findings from an independent review of studies suggests that currently available point-of-care (POC) tests are significantly less reliable than conventional microscopy, emphasizing the need for development of better and affordable POC diagnostics for schistosomiasis (bilharzia), classified as a neglected tropical diseases (NTD).

Simpler, more rapid POC tests with sufficient accuracy could replace microscopy for diagnosing schistosomiasis. The review was conducted by researchers from the Cochrane Infectious Diseases Group hosted at the Liverpool School of Tropical Medicine (LSTM; Liverpool, UK) to estimate accuracy of the circulating antigen (CA) test for urinary schistosomiasis and intestinal schistosomiasis, and of urine reagent (URStrip) tests for urinary schistosomiasis.

Two independent authors identified and assessed 90 studies involving almost 200,000 people, with 88 of the studies from field settings in Africa. Studies compared POC tests to microscopy as reference standard: for Schistosoma haematobium—microscopy of urine prepared by filtration, centrifugation, or sedimentation; for S. mansoni—microscopy of stool by Kato-Katz thick smear.

Among the URStrip tests for urinary schistosomiasis, those for detecting blood (microhaematuria) were more accurate than those for detecting protein (proteinuria) or white cells (leukocyturia). Sensitivity and specificity estimates: for blood 75% and 87%; for protein 61% and 82%; for white cells 58% and 61%, respectively.

For urinary schistosomiasis, CA test performance was worse (39% sensitivity, 78% specificity) than URStrips for blood. For intestinal schistosomiasis, CA test detected many infections identified by microscopy but wrongly labeled many uninfected people as infected (89% sensitivity, 55% specificity).

“The simple test using a strip for testing blood in the urine worked well. The antigen tests for the disease did not work so well for urinary schistosomiasis, and in intestinal schistosomiasis it may classify many uninfected people as infected and lead to unnecessary treatment,” said lead author Dr. Eleanor Ochodo, Stellenbosch University.

LSTM’s Prof. Russell Stothard, international expert in schistosomiasis and director of the new COUNTDOWN research consortium, which will trial and evaluate new approaches to drug distribution in NTD program, said: “Those in the field of NTD research and control welcome reviews of this kind, looking at the efficacy of diagnostic tests for diseases affecting some of the poorest communities in the world. They draw together largely fragmented literature into one place, allowing quick appraisal for informed decision-making. Reviews such as this will ensure that COUNTDOWN benefits from the best research intelligence from within the NTD community and stays well informed throughout.”

The review, by Ochodo EA et al., was published online March 11, 2015, in Cochrane Database of Systematic Reviews.

Related Links:

Cochrane Infectious Diseases Group
Liverpool School of Tropical Medicine (LSTM)


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.