We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Rapid Detection in Blood Cultures of ESBL-Producing Enterobacteriaceae

By LabMedica International staff writers
Posted on 04 Mar 2015
Print article
Image: The Vitek MS matrix-assisted laser desorption/ionization time-of-flight mass spectrometer (Photo courtesy of bioMérieux).
Image: The Vitek MS matrix-assisted laser desorption/ionization time-of-flight mass spectrometer (Photo courtesy of bioMérieux).
Image: The BacT/ALERT 3D Dual-T apparatus for microbial detection (Photo courtesy of bioMérieux).
Image: The BacT/ALERT 3D Dual-T apparatus for microbial detection (Photo courtesy of bioMérieux).
Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) technology has been used directly with blood cultures and was found to help guide clinical management of bacteremia caused by gram-negative bacteria (GNB).

Resistance to broad-spectrum cephalosporins is spreading rapidly among Enterobacteriaceae, mostly related to acquisition of extended-spectrum β-lactamases (ESBLs) and ESBL-producing Enterobacteriaceae (ESBL-E) are usually resistant to most β-lactams except cephamycins and carbapenems.

Microbiologist at the Institut National de la Santé et de la Recherche Médicale (Le Kremlin–Bicêtre, France) and their European colleagues studied a single blood culture positive for GNB from each of 245 hospitalized patients. They performed antibiotic susceptibility testing (AST) by the disk diffusion method using bacterial colonies grown from blood cultures and used the double-disk synergy test (DDST) for the phenotypic detection of ESBL producers.

Positivity of blood cultures was detected by using the BacT/Alert system (bioMérieux; La Balme-les-Grottes, France). After obtaining Gram stain results, they tested the blood cultures positive for GNB directly for ESBL-E by using the ESBL Nordmann/Dortet/Poirel (NDP) test and species identification by using the bioMérieux Vitek MS MALDI-TOF MS technique. They also used molecular biology techniques to identify the ESBL genes using polymerase chain reaction (PCR) to amplify the DNA.

The 245 cases of bacteremia were attributed to Enterobacteriaceae (86.1%), nonfermentative GNB (12.7%), and anaerobic GNB (1.2%). Escherichia coli was the predominant enterobacterial species (55.9%); the next most prevalent were Klebsiella pneumoniae (17.5%) and Enterobacter cloacae (9.5%). Pseudomonas aeruginosa (24/31, 77.4%) was the predominant non-fermentative GNB. Anaerobic GNB belonged to the Bacteroides fragilis group (Bacillus fragilis and B. vulgatus). The team identified bacteria directly from blood culture using the MALDI-TOF technique for 237 (96.7%) isolates and the results corresponded to bacterial identification after culture.

The authors concluded that the ESBL NDP test directly performed on positive blood cultures is a reliable technique to identify ESBL-E within 30 minutes. A strong correlation between intermediate susceptibility or resistance to cefotaxime and positivity of the ESBL NDP test was observed. The inexpensive ESBL NDP test might be implemented worldwide. It may optimize rapid choices of antibiotics for treating bloodstream infections. It may also contribute to avoidance of overuse of carbapenems. Finally, a rapid detection of ESBL-E coupled with bacterial species identification will enhance identification of ESBL in species likely to be the source of nosocomial outbreak and facilitate implementation of a rapid strategy for containment. The study was published in the March 2015 issue of the journal Emerging Infectious Diseases.

Related Links:

Institut National de la Santé et de la Recherche Médicale 
bioMérieux


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.