We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Infection Can Lead to False Negatives for Cerebrospinal Fluid β-2 Transferrin

By LabMedica International staff writers
Posted on 21 Oct 2014
Print article
Image: Scanning Electron Micrograph of Streptococcus pneumoniae by R. Facklam, J. Carr. Cerebrospinal fluid (CSF) β-2 transferrin detection decreases after inoculation with live or ciprofloxacin-inactived S. pneumoniae. This may be due to passive adsorption via distinctive features of the S. pneumoniae cell wall not present in the other bacterial species examined (Photo courtesy of MicrobeWiki and the CDC – [US] Centers for Disease Control and Prevention).
Image: Scanning Electron Micrograph of Streptococcus pneumoniae by R. Facklam, J. Carr. Cerebrospinal fluid (CSF) β-2 transferrin detection decreases after inoculation with live or ciprofloxacin-inactived S. pneumoniae. This may be due to passive adsorption via distinctive features of the S. pneumoniae cell wall not present in the other bacterial species examined (Photo courtesy of MicrobeWiki and the CDC – [US] Centers for Disease Control and Prevention).
Researchers have found that the presence of Streptococcus pneumoniae in cerebrospinal fluid (CSF) can lead to false-negative β-2 transferrin (β2TRNSF) test results and misdiagnosis that may detrimentally affect healthcare decisions for patients.

Free passage of bacterial flora from the nasal cavity and paranasal sinuses through a CSF fistula into the cranium may pose increased risk for meningitis and encephalitis. Thus, early diagnosis and treatment of CSF leakage could decrease the risk of a lethal infection. Although β2TRNSF is a highly reliable marker for diagnosing cases of CSF leakage (even in CSF contaminated with blood or other secretions)—it has not been examined in the presence of central nervous system bacterial infection.

In a prospective analysis, a team led by Nir Hirshoren, MD, at the Hebrew University School of Medicine–Hadassah Medical Center (Jerusalem, Israel) examined β2TRNSFdetection in artificially contaminated CSF as a research model. Sterile (tested for sterility) CSF was drawn from 9 prospectively-recruited neurosurgical patients. CSF samples were contaminated in vitro by controlled spiking with bacteria, chosen for ability to cause meningeal neurosurgical-related infections: Streptococcus pneumoniae, methicillin-sensitive Staphylococcus aureus (MSSA), Staphylococcus epidermidis, or Pseudomonas aeruginosa.

β2TRNSF analysis was performed using qualitative immunoblotting electrophoresis and quantitative enzyme-linked immunosorbent assay (ELISA). Two time points were examined, following immediate inoculation (t0 ) and following an overnight incubation (t18 ), over various bacterial-load concentrations. In this study, only S. pneumoniae was observed to significantly affect β2TRNSF detection. At both the t0 and t18 time points following S. pneumoniae inoculation, β2TRNSF was not detected when immunoblotting electrophoresis was used; quantitative analysis using ELISA demonstrated significant β2TRNSF concentration decrease.

A secondary objective of the study was to explore whether the disappearance of β2TRNSF in the assays is due to a passive or active mechanism. The researchers suspected that in some cases of bacterial infections, β2TRNSF might be adsorbed, degraded, or consumed by bacteria. CSF inoculated with S. pneumoniae was also examined in the presence of the non-cell-wall antibiotic ciprofloxacin, which led to the same results. Since β2TRNSF detection decreased also with inactivated (i.e. + ciprofloxacin) S. pneumoniae, a passive process was suggested, possibly due to adsorption via distinctive features of the S. pneumoniae cell wall not present in the other species examined.

The authors note that although the study was limited by a small sample number (n=9), potential bias was largely overcome by exploring different bacterial loads, examining diverse clinical bacterial species, and using two reliable assays. Further investigation in the clinical setting is needed, however the results indicate that, in the presence of a S. pneumoniae cerebral nervous system infection, using a β2TRNSF test for CFS leak detection may be deceiving and should be interpreted cautiously.

The authors further caution that the importance of β2TRNSF assays is limited to borderline, clinical-uncertainty cases. In other cases, a β2TRNSF negative result may not change a clinical decision regardless of CSF S. pneumoniae presence, and appropriate imaging modalities and surgery may be warranted anyway.

The study was reported by Korem M. et al. in the journal Laryngoscope, September 29, 2014, online ahead of print.

Related Links:

Hebrew University School of Medicine – Hadassah Medical Center
Hebrew University Hadassah Medical School


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The new method could reduce undiagnosed cancer cases in less-developed regions (Photo courtesy of 123RF)

New Method Offers Sustainable Approach to Universal Metabolic Cancer Diagnosis

Globally, more than one billion people suffer from a high rate of missed disease diagnosis, highlighting the urgent need for more precise and affordable diagnostic tools. Such tools are especially crucial... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.