Image: Histology of a brain from a patient with cerebral malaria showing sequestration of parasites, pigmentation and obstruction of blood vessels (Photo courtesy of Chulalongkorn University).
Image: Histology of a brain from a patient with cerebral malaria showing sequestration of parasites, pigmentation and obstruction of blood vessels (Photo courtesy of Chulalongkorn University).
The detection, semi-quantification, and clinical use of the Plasmodium falciparum histidine-rich protein-2 (PfHRP-2) as a parasite antigen biomarker for cerebral malaria had been investigated.

The examination of the cerebrospinal fluid (CSF) in cerebral malaria cases typically shows normal parameters with normal protein, glucose, and low cell count and hitherto a CSF biomarker for cerebral malaria has yet to be identified.

An international team of scientists led by those from the Johns Hopkins Bloomberg School of Public Health (Baltimore, MD, USA) collected 73 CSF samples from Tanzanian children, 6 months to 9 years of age with P. falciparum parasitaemia. The CSF samples from nine Tanzanian children, who were microscopy negative for P. falciparum in peripheral blood, were also collected at the same site from 1994 to 1995. An additional 24 CSF samples were selected from archived CSF samples obtained from patients with neuroimmunological or neuroinflammatory conditions to use as controls.

The rapid diagnostic test (RDT) Binax NOW Malaria Test (Alere; Waltham, MA, USA), which detects both PfHRP-2 and panspecies aldolase was performed on the CSF samples. An immuno-polymerase chain reaction (PCR) was optimized and the real-time PCR amplifications were performed in a C1000 Thermal Cycler (Bio-Rad; Hercules, CA, USA). Western blots analysis was performed to compare some plasma and CSF samples.

The PfHRP-2 was detected in archival CSF samples from cerebral malaria patients from Tanzania both by a newly developed sensitive and specific immuno-PCR in 72 of 73 samples, and by rapid diagnostic tests in 62 of 73 samples. The geometric mean PfHRP-2 CSF concentration was 8.76 ng/mL with no significant differences in those who survived with 9.2 ng/mL, those who died with11.1 ng/mL, and those with neurologic sequelae with 10.8 ng/mL. The cerebral biomarker CSF PfHRP-2 was undetectable in all aparasitemic endemic and non-endemic control samples.

The authors concluded that the widely used RDTs for malaria may be useful in CSF detection of PfHRP-2 in patients with cerebral malaria. A total of 62 of 73 samples had at least 1 ng/mL PfHRP-2 concentration detectable, an amount well above the 100 pg limit of detection threshold, if 100 µL is used for the RDT. The CSF PfHRP2 is proportional to plasma such that detection in the CSF is reflective of elevated plasma or whole blood PfHRP2 seen in many studies of cerebral malaria. The study was published June 30, 2014, in the American Journal of Tropical Medicine and Hygiene.

Related Links:

Johns Hopkins Bloomberg School of Public Health
Alere
Bio-Rad



ADVANCED INSTRUMENTS
KARL HECHT GMBH & CO KG
DIASYS DIAGNOSTIC SYSTEMS
WATERS CORPORATION

Channels

Immunology

view channel

Powerful Innovations in Diagnostics Unveiled at EuroMedLab 2015

New systems presented by Roche include a new standard for immunology testing, an integrated platform for hematology diagnostics, and a high-throughput analyzer to perform HbA1c tests for blood glucose management. Also, evidence was presented for a high-sensitivity cardiac troponin test to provide earlier and more accurate... Read more

Industry News

view channel

Cloud-Based Systems Becoming Key Pillar in eHealth Strategy

Cloud-based laboratory information management systems (LIMS) are becoming a key pillar in Europe’s e-Health strategy as data-management solutions for modern testing will generate more demand for these systems. Investments in cloud-based LIMS are part of Europe’s e-Health strategy. New analysis from Frost & Sullivan... Read more
 
Copyright © 2000-2015 Globetech Media. All rights reserved.