We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

R-BIOPHARM

R-Biopharm AG is a biotechnology company that offers innovative products for numerous applications in the area of cli... read more Featured Products: More products

Download Mobile App




Rapid Commercial Test for Campylobacter Evaluated

By LabMedica International staff writers
Posted on 13 Feb 2014
Print article
Image: Scanning electron micrograph of Campylobacter jejuni (Photo courtesy of Jonas Waldenström).
Image: Scanning electron micrograph of Campylobacter jejuni (Photo courtesy of Jonas Waldenström).
The effectiveness of a new rapid immunochromatographic test for the qualitative detection of Campylobacter antigens in pathologic feces has been evaluated.

The genus Campylobacter belongs to the family Campylobacteriaceae and contains 18 species, including Campylobacter jejuni, the cause of around 90% of acute Campylobacter enteritis cases in humans, a zoonotic disease prevalent worldwide and transmitted via water and food.

Microbiologists at the Hospital Universitario Virgen de las Nieves (Granada, Spain) examined 300 consecutive samples of fresh feces samples from patients diagnosed with diarrhea in primary (57.6%) and specialist (42.4%) care; 50.6% were from adults and 49.4% from children under 14 years of age, between March and May 2013. They were processed for coproculture immediately on their reception by culture and colonies suspected of being enteropathogenic were identified by means of the Biotyper system (Bruker Daltonics; Billerica, MA, USA).

The RIDAQUICK Campylobacter immunochromatographic test (R-biopharm AG; Darmstadt, Germany) was evaluated and compared with culture results. Campylobacter was considered present when the microorganism was isolated or when the specific DNA was detected in samples with contradictory culture and immunochromatographic findings. The results of the RIDAQUICK Campylobacter test was considered positive when violet red lines could be seen in the control (C) and test (T) bands, negative when the control line alone appeared, and invalid when no line could be observed.

Campylobacter was detected in 37 (12.3%) of all samples, and the gold-standard culture method was positive for C. jejuni in 31 (83.78%) of these. A different enteropathogen was detected in 12 (8.11%) of the samples from children. The culture and immunochromatographic results differed in 12 samples (4% of the total), which were therefore studied by polymerase chain reaction (PCR); six of these samples were culture-negative and PCR-positive and one was culture positive (C. jejuni) and PCR-negative.

The diagnostic accuracy values of the RIDAQUICK Campylobacter assay versus culture were: sensitivity of 87%, specificity of 97%, and positive and negative predictive values of 77% and 98%, respectively. RIDAQUICK Campylobacter was found to be a rapid test for the diagnosis of enteritis due to Campylobacter and could be an option for the clinical diagnosis of one of the main causes of bacterial enteritis in resource-limited settings. The study was published in the February 2014 issue of the journal Diagnostic Microbiology and Infectious Disease.

Related Links:

Hospital Universitario Virgen de las Nieves
Bruker Daltonics
R-biopharm AG


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.