Performance of Second Generation Cortisol Assay Evaluated

By LabMedica International staff writers
Posted on 21 Dec 2016
Print article
Image: The cobas e 411 fully automated, random access system for immunoassay analysis (Photo courtesy of Roche Diagnostics).
Image: The cobas e 411 fully automated, random access system for immunoassay analysis (Photo courtesy of Roche Diagnostics).
Untreated disorders of the adrenocortical system, such as Cushing’s or Addison’s disease, can be fatal, and accurate quantification of a patient’s cortisol levels is vital for diagnosis. A straightforward diagnostic approach is of essential importance, and accurate quantification of cortisol levels plays a key role in the diagnosis of patients with suspected disease.

Cortisol levels are often measured from a patient’s serum or plasma, which reflects total cortisol, both free and bound. However, in patients with liver disease, and for those receiving estrogen treatments or with critical illness, total serum cortisol levels may be difficult to interpret because of the variation in binding proteins.

Laboratory scientists at the Hospital of the University of Munich (Munich, Germany) and their colleagues performed a technical evaluation of the Elecsys Cortisol II assay (Roche Diagnostics GmbH, Mannheim, Germany) between June and November 2014 at four European investigational sites: three in Germany (Munich, Heidelberg, and Leipzig) and one in Belgium (Ghent). All sites used cobas e 411 analyzers for the Cortisol II assay experiments and in addition to a cobas e 411 system, the Leipzig site utilized a cobas e 601 analyzer. The Cortisol II assay was also compared with in-house isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays.

The team reported that for the method comparison studies, the serum samples covered a measuring range of 1.7 to 1,735 nmol/L and the saliva samples from 1.5 to 209.5 nmol/L. For the 405 serum samples, the agreement between the Cortisol II assay and LC-MS/MS was high, and the mean bias for serum samples measured on the Cortisol II assay compared with LC-MS/MS was 14.55 nmol/L. The correlation coefficient for the relationship between the Cortisol II assays versus LC-MS/MS for 253 saliva samples was 0.993, and for these comparisons, the mean bias was 2.56 nmol/L.

The authors concluded that for the Cortisol II assay, they observed a degree of between-laboratory and between-production lot reproducibility and agreement with several assays of higher metrological order that they consider compatible with the diagnostic use of this assay. The Cortisol II assay will be beneficial to endocrinologists in assessing patients with adreno-cortisol disorders. The study was published on November 29, 2016, in the journal Clinical Chemistry and Laboratory Medicine.

Related Links:
Hospital of the University of Munich
Roche Diagnostics

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: The new method could reduce undiagnosed cancer cases in less-developed regions (Photo courtesy of 123RF)

New Method Offers Sustainable Approach to Universal Metabolic Cancer Diagnosis

Globally, more than one billion people suffer from a high rate of missed disease diagnosis, highlighting the urgent need for more precise and affordable diagnostic tools. Such tools are especially crucial... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.