Early-Detection Urine Test Is Effective for Lyme Disease

By LabMedica International staff writers
Posted on 01 Jun 2016
Print article
Image: The typical erythema migrans or bulls-eye rash often but not always seen in Lyme disease (Photo courtesy of the CDC).
Image: The typical erythema migrans or bulls-eye rash often but not always seen in Lyme disease (Photo courtesy of the CDC).
Prompt antibiotic treatment of early stage Lyme Borreliosis (LB) prevents progression to severe multisystem disease and there is a clinical need to improve the diagnostic specificity of early stage Lyme assays in the period prior to the mounting of a robust serology response.

The clinical presentation of LB can be so varied; early stage disease can be misdiagnosed for a variety of reasons including failure to develop an erythema migrans (EM) rash, failure of the patient or clinician to recognize an EM rash, if present, the non-specific nature of early symptoms and a negative or ambiguous serology.

Scientists at the George Mason University (Fairfax, VA, USA) obtained mid-stream urine specimens that were self-collected by 268 participants with all stages of documented or suspected Lyme disease. Whole blood from each subject was drawn on the same day as urine collection. Blood samples were sent to Quest Diagnostics (Madison, NJ, USA) for Total Lyme Disease Antibody (EIA) and Lyme immunoglobulin G (IgG) and IgM Western Blot tests.

The scientists employed Nanotrap particles (Ceres Nanosciences, Manassas, VA, USA) to concentrate urinary OspA and used a highly specific anti-OspA monoclonal antibody (mAb) as a detector of the C-terminus peptides. They mapped the mAb epitope to a narrow specific OspA C-terminal domain OspA236-239 conserved across infectious Borrelia species but with no homology to human proteins and no cross-reactivity with relevant viral and non-Borrelia bacterial proteins. They collected 268 urine samples from patients being evaluated for all categories of LB in a LB endemic area. The urinary OspA assay, blinded to outcome, utilized Nanotrap particle pre-processing, western blotting to evaluate the OspA molecular size, and OspA peptide competition for confirmation.

The team found that in pre-treatment, 24/24 newly diagnosed patients with an erythema migrans (EM) rash were positive for urinary OspA while false positives for asymptomatic patients were 0/117. For 10 patients who exhibited persistence of the EM rash during the course of antibiotic therapy, 10/10 were positive for urinary OspA. Urinary OspA of 8/8 patients switched from detectable to undetectable following symptom resolution post-treatment. Specificity of the urinary OspA test for the clinical symptoms was 40/40. Specificity of the urinary OspA antigen test for later serology outcome was 87.5 % (21 urinary OspA positive/24 serology positive, and 41 of 100 patients under surveillance for persistent LB in an endemic area were positive for urinary OspA protein.

Alessandra Luchini, PhD, a professor and lead investigator of the study, said, “We're looking to repeat the story again with these other diseases. Other targets for the new type of test include Chagas disease, which is infectious and caused by a parasite, and toxoplasmosis, another parasite-borne disease.” The study was published originally published online on November 4, 2015, in the Journal of Translational Medicine.

Related Links:
George Mason University
Quest Diagnostics
Ceres Nanosciences
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.