Zika Virus Inactivated in Plasma for Transfusion

By LabMedica International staff writers
Posted on 03 Apr 2016
The potential for Zika virus (ZIKV) transmission through blood transfusion has been demonstrated during the French Polynesian outbreak as 2.8% of blood donors, who were asymptomatic at the time of donation, were found positive for acute ZIKV infection using specific reverse transcription–polymerase chain reaction (RT-PCR). More...


Several processes have been developed for the inactivation of pathogens during the preparation of fresh-frozen plasma (FFP) and platelet (PLT) concentrates. Among them, a photochemical treatment using the psoralen, amotosalen, S-59, in combination with ultraviolet A (UVA) illumination, has been shown to inactivate a broad range of viruses, bacteria, and protozoans.

A team of scientists working with those at the Institut Louis Malardé (Papeete, Tahiti, French Polynesia) collected plasma units from USA blood donors to eliminate risk of ZIKV antibodies. To assess the absence of previous infections by Flaviviruses known to circulate in the USA, Dengue and West Nile (DENV and WNV), each plasma unit was tested with a dengue immunoglobulin (Ig)G capture kit (Platelia, Bio-Rad; Hercules, CA, USA) and a classic WNV IgG kit (Serion Elisa, Abcam; Cambridge, UK), to detect IgG antibodies against DENV and WNV, respectively. The 26 sera of French Polynesian ZIKV-infected and asymptomatic blood donors were obtained from the blood bank center of French Polynesia.

Four plasma units (A, B, C, and D) were inoculated with ZIKV. A sample from each infected plasma unit (pre-inactivation sample) was then collected and stored at -80 °C until the determination of viral titers and RNA loads. Inoculated Plasma Units A, B, and C were treated with amotosalen combined with UVA illumination, whereas inoculated Plasma Unit D was not inactivated and was the positive control. After transfer into a container with a compound absorption device that removes the residual amotosalen and the free photoproducts, samples from each inactivated plasma unit (inactivated samples) and from the positive control (non-inactivated sample) were collected and stored at -80 °C until the determination of viral titers and RNA loads.

For the detection of replicative ZIKV, all pre-, post-, and non-inactivated samples were inoculated in triplicate on VERO cells in 24-well plates, and five successive passages were performed. After each passage, indirect immunofluorescence assay was performed to detect ZIKV inoculated cells, using anti-flavivirus mouse antibodies 4G2. For all plasma (pre-, post-, and non-inactivated samples), cell supernatant, and serum samples, RNA extraction was performed using an extraction system and real-time RT-PCR was performed in a Bio-Rad CFX96 thermocycler.

The mean ZIKV titers and RNA loads in plasma before inactivation were respectively 6.57 log 50% tissue culture infectious dose (TCID50)/mL and 10.25 log copies/mL. After inactivation, the mean ZIKV RNA loads was 9.51 log copies/mL, but cell cultures inoculated with inactivated plasma did not result in infected cells and did not produce any replicative virus after one passage, nor detectable viral RNA from the second passage. The authors concluded that amotosalen combined with UVA light inactivates ZIKV in fresh-frozen plasma. This inactivation process is of particular interest to prevent plasma transfusion-transmitted ZIKV infections in areas such as French Polynesia, where several arboviruses are co-circulating. The study was published in the January 2016 issue of the journal Transfusion.

Related Links:

Institut Louis Malardé
Bio-Rad 
Abcam 



Gold Member
Fibrinolysis Assay
HemosIL Fibrinolysis Assay Panel
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Sperm Quality Analyis Kit
QwikCheck Beads Precision and Linearity Kit
8-Channel Pipette
SAPPHIRE 20–300 µL
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.