We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

Download Mobile App




TB Tests Assessed to Diagnose Pregnant HIV Positive Women

By LabMedica International staff writers
Posted on 09 Feb 2016
Print article
Image: QuantiFERON Gold interferon gamma release assay for tuberculosis (Photo courtesy of Statens Serum Institut).
Image: QuantiFERON Gold interferon gamma release assay for tuberculosis (Photo courtesy of Statens Serum Institut).
The most commonly used test for tuberculosis (TB) fails to accurately diagnose the disease in up to 50% percent of pregnant women who are positive for the human immunodeficiency virus (HIV+).

The performance of latent TB infection (LTBI) tests has been assessed in HIV-infected pregnant and postpartum women, and the immunology behind discordance in pregnancy investigated, and the implications for the development of postpartum tuberculosis explored.

Scientists at the Weill Cornell Medical College (New York, NY, USA) and their colleagues form other institutions enrolled 252 women who were in their second or third trimester and receiving care at a public teaching hospital in India. The women received TB testing at enrollment during pregnancy or at delivery. An additional 39 women participated in a longitudinal study to assess how the TB tests were affected by changes in different stages of pregnancy. They were tested at delivery and three months postpartum. The investigators also collected blood samples to assess for levels of infection-fighting proteins.

The teams screened pregnant women in their 2nd/3rd trimester and at delivery for LTBI using the tuberculin skin test (TST) and QuantiFERON Gold interferon gamma release assay (IGRA), (Quest Diagnostics; Madison, NJ, USA). A subset of antepartum women had longitudinal testing, with repeat testing at delivery and postpartum and additional cytokines measured from the IGRA supernatant. Of 252 enrolled, 71 (28%) women had a positive IGRA, but only 27 (10%) had a positive TST, and there was 75% agreement. When stratified by pregnancy versus delivery, 20% had IGRA+/TST- discordance at each time point. A positive IGRA was associated with known TB contact. Compared to IGRA+/TST+, women with IGRA+/TST- discordance produced significantly less interferon gamma (IFN-γ; 1.85 IU/mL vs 3.48 IU/mL, and less interleukin 2 (IL-2; 46.17 pg/mL vs. 84.03 pg/mL). Five developed postpartum tuberculosis, of which three had IGRA+/TST- discordance during pregnancy.

Jyoti Mathad, MD, MSc, the lead author of study said, “We found that QuantiFERON Gold positivity was almost three times higher than the more widely used TST at every time point tested. Our blood data suggests that pregnant women produce lower levels of the immune chemicals that many TB diagnostics test for. This finding has implications beyond diagnostics. For example, not all pregnant women lose immune control of TB infection. But, currently we have no way of predicting which women are most likely to get sick from the disease. Our findings about these immune chemicals provide a starting point for developing a test that will tell us who in this already high-risk population is at greatest risk of disease and death and is in most need of treatment.” The study was published on January 14, 2016, in the American Journal of Respiratory and Critical Care Medicine.

Related Links:

Weill Cornell Medical College 
Quest Diagnostics


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Liquid biopsy could detect and monitor aggressive small cell lung cancer (Photo courtesy of Shutterstock)

Blood-Based Test Detects and Monitors Aggressive Small Cell Lung Cancer

Small cell lung cancer (SCLC) is a highly aggressive type of cancer known for its ability to metastasize. The behavior of tumors is largely governed by which genes are turned on, or transcribed, irrespective... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.