New Ultrasensitive Test Developed for Peanut Allergies

By LabMedica International staff writers
Posted on 09 Mar 2015
Print article
Image: The surface plasmon resonance SPRimager II (Photo courtesy of GWC Technologies).
Image: The surface plasmon resonance SPRimager II (Photo courtesy of GWC Technologies).
Current peanut allergy tests are not very reliable when it comes to diagnosing the severity of an individual's allergic reaction, which can range from hives to life-threatening anaphylactic shock.

Severity of peanut allergies is linked to allergen-specific immunoglobulin E (IgE) antibodies in blood, but diagnostics from assays using glycoprotein allergen mixtures may be inaccurate. However measuring IgEs specific to individual peptide and carbohydrate epitopes of allergenic proteins is promising.

Chemists at the University of Connecticut (Storrs, CT, USA) are developing a more advanced peanut allergy test that, based on initial results, is many times more sensitive than current procedures. The new test is capable of determining the potential intensity of a patient's allergic reaction through just a few drops of blood.

In an allergic person who eats peanuts, their immune system releases an antibody protein known as IgE. These antibodies fight off peanut allergen molecules by binding to them and flushing them out of the body. The release of the antibodies causes tissue cells in the body to produce histamine, which in turn generates a variety of allergy symptoms such as itchy skin, runny nose, coughing, or wheezing. The more antibodies that are released, the more histamine is generated, the stronger the person's allergic response.

The scientists created an immunoarray for IgEs utilizing both peptide and carbohydrate epitopes. A surface plasmon resonance imaging (SPRi) microarray was equipped with peptide and β-xylosyl glycoside (BXG) epitopes from major peanut allergen glycoprotein Arachis hypogaea h2 (Ara-h2). A monoclonal anti-IgE antibody was included as positive control. IgEs were precaptured onto magnetic beads loaded with polyclonal anti-IgE antibodies to enhance sensitivity and minimize nonspecific binding.

The binding of IgE antibody to allergen epitopes was studied using a Surface Plasmon Resonance (SPR) imager (SPRimager II, GWC Technologies; Madison, WI, USA) interfaced with syringe pump and injection valve and sensor chip was assembled into the SPR imaging instrument. The chemists then injected blood serum from patients known to have peanut allergies into the array. As the blood serum floated over the samples, IgE antibodies were pulled down by the allergens and bound by them. They could then measure the quantity of antibodies to determine how strong a reaction a person would have to peanuts. To further refine the system, the team attached magnetic beads to the allergen samples. The beads captured the IgEs and amplified the final measurements, allowing them to detect concentrations of antibodies as low as 0.5 to 1 pg/mL.

James A. Rusling, PhD, a professor who led the study said, “A patient who has a serious allergy and gets exposed to an allergen protein will form antibodies in their body that should stay there for a while. Our theory is that the level of those antibodies can be used to predict how severe a patient's allergy is at any one point in time. Eventually, we'd like to use maybe five different peptides and carbohydrate samples to see how these IgEs bind to them. That way, we could determine a clear fingerprint of a patient's susceptibility to a specific allergen.” The study was originally published online on September 16, 2014, in the journal the Analyst.

Related Links:

University of Connecticut 
GWC Technologies 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The real-time multiplex PCR test is set to revolutionize early sepsis detection (Photo courtesy of Shutterstock)

1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens

Sepsis contributes to one in every three hospital deaths in the US, and globally, septic shock carries a mortality rate of 30-40%. Diagnosing sepsis early is challenging due to its non-specific symptoms... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.