Automated Chemiluminescent Assays Evaluated for Heparin-Induced Antibodies

By LabMedica International staff writers
Posted on 30 Aug 2012
Two recently introduced automated chemiluminescent assays for the detection of antibodies have been evaluated in the diagnosis of heparin-induced thrombocytopenia.

The performance of the two assays was compared with enzyme linked immunosorbent assays (ELISA) heparin-induced antibodies (HIA) tests for immunoglobulins IgG and IgAM. More...


Scientists at Ghent University Hospital (Belgium) collected citrated plasmas from 87 patients with clinical suspicion of heparin-induced thrombocytopenia (HIT) were analyzed with all four assays and with a functional confirmation assay. The Zymutest HIA IgG and HIA IgGAM assays (Aniara; West Chester, OH, USA) are micro-ELISAs, that take over two hours to perform, were used as the standard reference.

The fully automated quantitative chemiluminescent immunoassays, the HemosIL AcuStar HIT-IgG (Platelet Factor 4-Heparin, PF4-H), specific for IgG anti-PF4/H antibodies, and the HemosIL AcuStar HIT-Ab (PF4-H), detecting IgG, IgM and IgA anti-PF4/H antibodies are products of Instrumentation Laboratory (Bedford, MA, USA). They provide enhanced detection of HIT antibodies in specialty and hospital hemostasis laboratories. Unlike existing manual processes, the ready-to-use, cartridge-based assays offer results in approximately 30 minutes.

The sensitivities of all assays were 100%. The Acustar HIT-IgG assay showed 85% specificity compared to the 73% for the HIT-Ab assay using the manufacturer’s cutoffs. Specificities of all assays, except for the AcuStar HIT-IgG, could be significantly improved when altering the cutoff. Titers were significantly higher for the HIT-Ab assay compared with the HIT-IgG assay. This was also the case for the patients with confirmed HIT indicating that the cutoff of 1.0 Optical Density (OD) for both AcuStar assays, as proposed by the manufacturer, can be adapted for the AcuStar Hit-Ab assay resulting in an increased specificity.

Chemiluminescent technology provides analytical excellence through an expansive working range for high sensitivity and precision allowing clinicians to make timely, well-informed therapeutic decisions. In addition, the Acustar HIT precalibrated reagent cartridges offer significant time- and cost- efficiencies. The study was published in the August 2012 edition of the International Journal of Laboratory Hematology.

Related Links:

Ghent University Hospital
Aniara
Instrumentation Laboratory



Gold Member
Quantitative POC Immunoassay Analyzer
EASY READER+
Online QC Software
Acusera 24•7
All-in-One Molecular System
AIO M160
Food Allergy Screening ELISA Kit
Allerquant 14G B ELISA
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: Researchers use a novel immobilized liposome-bound gel beads method to measure CEC levels and their association with cardiovascular risks (Photo courtesy of Institute of Science Tokyo)

Simple Blood-Based Cholesterol Efflux Assay Identifies High-Risk Coronary Plaque Features

Unstable coronary plaques are difficult to identify before they trigger acute cardiovascular events. Standard high-density lipoprotein (HDL) measurements do not always capture how well HDL particles function... Read more

Pathology

view channel
Image: Overview of the uncertainty-aware lensfree computational pathology platform for automated HER2 assessment. A compact lensfree holographic imaging system captures diffraction patterns from immunohistochemically stained breast tissue samples, which are computationally reconstructed and analyzed using deep neural networks with Bayesian uncertainty quantification. (Photo courtesy of Ozcan Lab, UCLA)

Uncertainty-Aware AI Platform Supports Automated HER2 Assessment in Breast Cancer

Accurate assessment of human epidermal growth factor receptor 2 (HER2) is critical for breast cancer diagnosis and treatment selection, yet scoring variability and infrastructure requirements can complicate... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.