Classical Microscopy Outperforms Automated Urine Analysis

By LabMedica International staff writers
Posted on 07 May 2014
Print article
Image: Urinary Casts as viewed by microscopy (A) Hyaline cast (×200); (B) erythrocyte cast (×100 ); (C) leukocyte cast (×100) ; (D) granular cast (×100) (Photo courtesy of the American Family Physician).
Image: Urinary Casts as viewed by microscopy (A) Hyaline cast (×200); (B) erythrocyte cast (×100 ); (C) leukocyte cast (×100) ; (D) granular cast (×100) (Photo courtesy of the American Family Physician).
The human eye using a microscope can be more accurate than automation when it comes to analyzing urine samples for signs of kidney damage.

An automated urine analysis system can miss signs of kidney damage that can easily be identified by a trained observer looking through a compound microscope at the urine sample.

A team of scientists at the University of Arizona (Phoenix, AZ, USA) investigated how well each approach, microscopy and automated analysis, was able to identify granular and muddy brown casts, tiny tube-like structures made of protein secreted by the kidney. Casts in the setting of kidney damage can help identify the underlying problem such as inflammation or infection, and counting them and identifying their characteristics and composition can provide important diagnostic and prognostic information.

Each of the 10 samples analyzed were from patients with acute kidney injury. A single person analyzed each urine sample, first by examining it under the microscope, and then with the automated IRIS 200 urinary analysis system (Iris Diagnostics; Chatsworth, CA, USA). The IRIS 200 system coded 70% of the samples as having no casts. All of the samples were classified as having few casts using manual microscopy. The samples that were automatically coded on IRIS 200 as having many casts were also coded as few by manual microscopy.

Natasha Sharda, MD, the lead investigator, said, “The automated system underreported the value of granular casts in our patient cohort of acute kidney injury. The automated system still has utility as a screening test, but manual microscopy should be done in all cases of abnormal kidney function, as accurate quantification of casts could have some prognostic benefit to patients. Even though the automated urinalysis system has many benefits, it should not replace direct observation, but rather be used as augmentation.”

Thomas Manley, director of scientific activities at the National Kidney Foundation (New York, NY, USA) added, “Technological advances in medicine have been extremely valuable in improving outcomes for patients, but in some cases the human eye is still superior to machines. In this study manual microscopy was superior to an automated urinalysis in evaluating urine sediment properties.” The study was presented at the National Kidney Foundation's 2014 Spring Clinical Meetings held April 22–26, 2014, in Las Vegas (NV, USA).

Related Links:

University of Arizona
Iris Diagnostics
National Kidney Foundation


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.