Rapid Urine Test Detects Early Kidney Injury

By LabMedica International staff writers
Posted on 05 May 2014
Print article
Image: The NephroCheck Test cartridge and Astute140 Meter (Photo courtesy of Astute Medical).
Image: The NephroCheck Test cartridge and Astute140 Meter (Photo courtesy of Astute Medical).
A new test utilizes fluorescence immunoassay technology to detect and measure two biomarkers that reflect the risk of developing acute kidney injury (AKI).

The NephroCheck Test measures tissue inhibitor of metalloproteinase 2 (TIMP-2) and insulin-like growth factor binding protein 7(IGFBP-7) in human urine. Both are involved in G1 cell cycle arrest during the very early phases of cellular stress, and are robust measures of risk for AKI manifesting within the following 12-24 hours. TIMP-2 is an inhibitor of the matrix metalloproteinases (MMPs) that directly suppress the proliferation of endothelial cells. IGFBP-7 is involved in the regulation of tissue availability of insulin and IGFs, and stimulates cell adhesion implicated in epithelial cell-cycle arrest.

For the test, a sample of a patient’s urine is mixed with reagents onto a single-use cartridge inserted into the proprietary Astute140 Meter. The meter employs a sandwich immunoassay technique along with fluorescence detection technology to quantitatively measure the biomarker concentrations, combining them into a single numerical test result. Multiple levels of controls (internal, external, and electronic) are used to ensure reliable and accurate results in about 20 minutes. The NephroCheck Test and Astute140 Meter are products of Astute Medical (San Diego, CA, USA), and have received the European Community CE marking of approval.

“We believe the NephroCheck Test will be able to help physicians address one of the most costly, deadly, and confounding conditions affecting intensive care hospital patients,” said Chris Hibberd, CEO of Astute Medical. “With increasing constraints on healthcare spending, innovative tools such as the NephroCheck Test will be essential to ensuring that the right resources get to the right patients at the right time.”

AKI is a significant global health hazard that strikes up to seven percent of hospitalized patients. AKI often occurs in patients that are already suffering from myriad issues such as sepsis, trauma, surgery, or being treated with nephrotoxic drugs, further complicating diagnosis, while also increasing mortality rates.

Related Links:

Astute Medical


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The real-time multiplex PCR test is set to revolutionize early sepsis detection (Photo courtesy of Shutterstock)

1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens

Sepsis contributes to one in every three hospital deaths in the US, and globally, septic shock carries a mortality rate of 30-40%. Diagnosing sepsis early is challenging due to its non-specific symptoms... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.