Unnecessary Endoscopies Could Be Avoided with Fecal Blood Test

By LabMedica International staff writers
Posted on 14 Oct 2016
The majority of primary care patients referred for bowel endoscopy do not have significant colorectal disease (SCD), and are unnecessarily exposed to a small but realistic risk of severe endoscopy-associated complications.

Serious colorectal diseases, including colorectal cancer, are difficult to diagnose as the signs and symptoms are not always clear. More...
Any suspicion of SCD requires a general practitioner referral to a hospital for an endoscopy but studies have shown that between 60% to 80% of referred patients end up not having SCD.

Scientists at the University Medical Center Utrecht (Netherlands) collected data from the large-scale study where 810 patients suspected of SCD were enrolled from 266 primary care practices in the Netherlands. A pre-endoscopy venous blood sample was drawn to estimate hemoglobin and C-reactive protein (CRP) concentrations according to routine clinical practice. The team developed a diagnostic strategy to better exclude SCD in these patients and evaluated the value of adding a fecal calprotectin point-of-care (POC) and/or a POC fecal immunochemical test for hemoglobin (FIT-Hb)) to routine clinical information.

The investigators analyzed the fecal samples for calprotectin concentration by a quantitative point-of-care (POC) test (Quantum Blue; dynamic range 30 to 300 μg/g) and by an enzyme-linked immunosorbent assay (ELISA; EK-CAL Calprotectin ELISA, (both from Bühlmann Laboratories, Schönenbuch, Switzerland), both yielding estimates of μg calprotectin/g feces. For fecal Hb the team used a qualitative POC FIT, the Clearview iFOBT One Step Fecal Occult Blood Test Device, (Alere Health; Waltham, MA, USA), yielding either a positive or negative test result with a lower detection limit of 6 μg/g.

Out of the 810 patients referred for an endoscopy, 669 were found to have no SCD. Once the results of the FIT test had been taken into account the scientists found that approximately 30% of these patients could have been prevented from having an endoscopy as they may have been correctly diagnosed as not having SCD during their doctor’s visit. The study also looked at the benefit of adding a fecal test for the protein calprotectin to the diagnostic strategy. They found that this test also improved the diagnosis of SCD but not to the same extent as FIT. Furthermore, combining both tests added little extra benefit to the diagnostic accuracy of FIT alone.

The authors concluded that FIT and to a much lesser extent calprotectin POC testing showed incremental value for SCD diagnosis beyond standard clinical information. A diagnostic strategy with routine clinical data and a POC FIT test may safely rule out SCD and prevent unnecessary endoscopy referral in approximately one third of SCD-suspected primary care patients. The study was published on September 26, 2016, in the journal BMC Medicine.

Related Links:
University Medical Center Utrecht
Bühlmann Laboratories
Alere Health


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
NEW PRODUCT : SILICONE WASHING MACHINE TRAY COVER WITH VICOLAB SILICONE NET VICOLAB®
REGISTRED 682.9
New
Silver Member
Connectivity Solution
EKF Link
New
Microbiology Laboratory Automation Solution
BD Kiestra™ ReadA+BarcodA
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Microbiology

view channel
Image: Schematic overview of the CRISPR-Assisted Nanodroplet-pairing Platform for Differential Identification of NTM (CANDI). The platform combines broad-range amplification using conserved regions of the 16S and 23S rRNA genes with species-specific CRISPR recognition. Fluorescence-coded CRISPR droplets are paired with sample droplets containing amplified products, enabling multiplexed target recognition and signal decoding (Image Credit: Yiwen Yang, Jingsong Xu, Dakang Xu)

Nanodroplet CRISPR Technology Supports Rapid, Multiplexed Mycobacterial Identification

Mycobacterial infections are difficult to diagnose because closely related species can have different clinical and therapeutic implications. Nontuberculous mycobacteria (NTM) are increasingly recognized... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image: TruVerus is designed to deliver a broad menu of routine blood tests from a small blood sample on a single, automated benchtop platform (Photo courtesy of Truvian Health)

Collaboration Advances Automated Benchtop Platform for Routine Blood Testing

Routine blood testing is central to clinical decision-making, but access can vary across laboratory and healthcare settings. Broader use of automated benchtop platforms may help integrate testing more... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.