Reliable Diagnostic Test Developed for Scabies

By LabMedica International staff writers
Posted on 22 Nov 2011
Print article
A fluoroimmunoassay has been developed to determine the specific antibodies in the blood of patients infested with the human itch mite, Sarcoptes scabiei.

Scabies antigen specific immunoglobulin E (IgE) was measured by a dissociation-enhanced lanthanide fluoroimmunoassay (DELFIA) and quantified, while a competitive inhibition enzyme-linked immunosorbent assay (ELISA) was also conducted.

Scientists from the Menzies School of Health Research, (Darwin, NT, Australia) collaborated with other institutions, to create recombinant allergens to S. scabiei and house dust mites (HDM). Specific IgE antibodies to a major scabies antigen recombinant Sar s 14.3 (rSar s 14.3) were measured in 140 plasma samples from scabies-infested and control subject groups. The 140 consenting volunteers consisted of six groups: 30 subjects with crusted scabies; 30 subjects with ordinary scabies; 30 previously exposed but currently noninfested subjects; 30 subjects naïve to scabies; 10 naïve subjects with atopic allergy as defined by positive skin prick test to a panel of common aeroallergens; and 10 naïve subjects with known allergy to human dust mites based on clinical history and positive specific IgE.

The mean IgE binding to the recombinant antigen for the crusted scabies group was significantly greater compared to each of the other groups. The ordinary scabies group also had a significantly higher mean value than each noninfested group, and the exposed but noninfested group's mean IgE response was significantly greater than the mean response for the naïve to scabies group. The recombinant antigen DELFIA (Wallac; Turku, Finland) showed excellent diagnostic capability, with 100% sensitivity and 93.75% specificity for distinguishing subjects with current scabies infestation from control, uninfested subjects.

The authors concluded that the results demonstrate sensitive detection of IgE reactivity with genus-specific scabies mite epitopes and differential diagnosis of scabies mite allergy from allergy to HDM. The recombinant antigen specific IgE DELFIA has high diagnostic efficiency, with accuracy superior to other diagnostic methods currently available for scabies. Due to the high sensitivity, specificity, accuracy, predictive values, and area under the ROC curve, the developed DELFIA represents a marked improvement for the clinical diagnosis of scabies and helps direct future development of a specific diagnostic tool for scabies. The study was published on October 21, 2011, in the journal Diagnostic Microbiology and Infectious Disease.

Related Links:
Menzies School of Health Research
Wallac

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.