Diagnostic Tests Recognize Specific Disease Proteins

By LabMedica International staff writers
Posted on 19 Sep 2012
An antibody-free, targeted mass-spectrometric approach has been used for the quantification of proteins at low levels in human plasma and serum.

The method uses high-pressure, high-resolution separations coupled with intelligent selection and multiplexing for sensitive selected reaction monitoring-based targeted protein quantification and is known as PRISM. More...


A team of scientists at the Pacific Northwest National Laboratory found that their PRISM technique performed as accurately as standard clinical tests known as enzyme-linked immunosorbent assays (ELISAs) in a side-by-side comparison using blood samples from cancer patients. The tests measure biomarkers, proteins whose presence identifies a disease or condition.

To get around the need for an antibody, the team concentrated the proteins in their samples by using the technique called high performance liquid chromatography (HPLC), which concentrated the proteins about 100 times more than in the initial sample. The next step was to find their protein of interest in their concentrated samples.

With a potential biomarker in mind, the team made a version that was atomically denser. They synthesized the protein using carbon and nitrogen atoms that contain extra neutrons. The unusual atoms added weight but did not change any other characteristics. The heavier versions are twins of the lighter proteins found within the blood, cells, or samples. Although the twins behave similarly in the analytical instruments, the heavier twin is easily found among the sample's many proteins.

The sample was passed through the instrument to concentrate the proteins. The instrument separates the sample, one concentrated fraction at a time. The fraction that contained the heavy biomarker was also the fraction that contained its twin, the lighter, natural protein. From this fraction, the team could quantify the protein. The team spiked blood samples from women with a biomarker called the prostate specific antigen (PSA) that is only found in men. The team found they could measure PSA at concentrations about 50 pg/mL. While typical of the sensitivity of ELISA tests, it represents about 100 times the sensitivity of conventional mass spectrometry methods.

The team then tested PSA in samples from male cancer patients and found PRISM performed as well as ELISA. Interestingly, PRISM measured three times the amount of PSA than the ELISA assay did. This result suggests that antibody-based ELISA tests fail to measure all of the forms of the biomarker. Wei-Jun Qian, PhD, the senior author of the study, said, "Clinical tests have almost always used antibodies to measure biomarkers, because antibodies can provide good sensitivity, but it often takes a year and a half to develop antibodies as tools. Antibody development is one of the bottlenecks for new biomarker studies in disease and systems biology research." The study was published on the September 5 2012, in the Proceedings of the National Academy of Sciences of the United States of America (PNAS).

Related Links:

Pacific Northwest National Laboratory



Gold Member
Aspiration System
VACUSAFE
Online QC Software
Acusera 24•7
LAIR2 Antibody Pair Set
LAIR2 Antibody Pair [Biotin]
All-in-One Molecular System
AIO M160
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: Researchers use a novel immobilized liposome-bound gel beads method to measure CEC levels and their association with cardiovascular risks (Photo courtesy of Institute of Science Tokyo)

Simple Blood-Based Cholesterol Efflux Assay Identifies High-Risk Coronary Plaque Features

Unstable coronary plaques are difficult to identify before they trigger acute cardiovascular events. Standard high-density lipoprotein (HDL) measurements do not always capture how well HDL particles function... Read more

Pathology

view channel
Image: Overview of the uncertainty-aware lensfree computational pathology platform for automated HER2 assessment. A compact lensfree holographic imaging system captures diffraction patterns from immunohistochemically stained breast tissue samples, which are computationally reconstructed and analyzed using deep neural networks with Bayesian uncertainty quantification. (Photo courtesy of Ozcan Lab, UCLA)

Uncertainty-Aware AI Platform Supports Automated HER2 Assessment in Breast Cancer

Accurate assessment of human epidermal growth factor receptor 2 (HER2) is critical for breast cancer diagnosis and treatment selection, yet scoring variability and infrastructure requirements can complicate... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.