We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
INTEGRA BIOSCIENCES AG

Download Mobile App




Handheld Device Improves Targeted Cell Collection for Early Ovarian Cancer Assessment

By LabMedica International staff writers
Posted on 25 Sep 2026

High-grade serous ovarian cancer is the most common form of ovarian cancer, and many cases are thought to originate in the fallopian tubes. More...

Because precursor lesions can be microscopic, they are difficult to sample and detect at an early stage. Five-year survival can exceed 90% when ovarian cancer is diagnosed early, but falls below 50% when the disease is detected at stages 3 or 4. To improve access to these hard-to-sample tissues, researchers have developed a device that collects living cells from specific anatomical sites.

Researchers at the Massachusetts Institute of Technology (MIT; Cambridge, MA, USA), working with colleagues at Johns Hopkins University (Baltimore, MD, USA), developed a handheld fluidic-shear device for targeted cell collection. The 3D-printed microfluidic device uses one syringe to create a vacuum seal against the tissue. A second syringe drives liquid through a channel, generating shear stress that gently detaches cells from a small area while leaving surrounding tissue intact.

In a study published in Device on September 24, 2026, the researchers used the system to sample newly excised tissue and recover living cells for cultivation. They tested it on fresh human fallopian tube samples and compared its cell-collection performance with conventional approaches. Cells collected with the device remained viable and grew in culture more readily than cells detached by conventional methods. The team also used collected fallopian tube cells to grow organoids before returning the tissue samples for conventional pathology.

Tests across different cell types showed that the applied shear stress could be adjusted for collection. Loosely adherent prostate cancer cells detached at 1 pascal of stress. By contrast, only a few bone cancer cells detached at 5 pascals.

The researchers expect initial use to focus on tissue already removed from the body. They are also exploring optical approaches to identify suspicious regions that could then be sampled with the device. Future goals include collecting cells inside patients and using living patient-derived cells to study disease and test treatment responses.

“We wanted to collect living cells from specific regions of the fallopian tube while leaving the surrounding tissue intact. Once we have these living cells, there are many things we can do with them. We can use them for diagnostics, grow them into organoids and build living models of disease. Ultimately, this could allow us to test how an individual patient's cells respond to different treatments and help us develop more personalized medicines,” said Kripa Varanasi, senior author of the study and professor of mechanical engineering at MIT.

Related Links
MIT


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
βeta-Hydroxybutyrate Reagent
β-Hydroxybutyrate LiquiColor®
Automated Immunoassay Analyzer
SuperFlex™
Gold Member
Electrolyte Analyzer
CBS-4000 (CBS-400)
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image Credit: Shutterstock

Lung Cancer Atlas Reveals Cellular Patterns Associated With Patient Prognosis

Lung cancer is a leading cause of cancer-related death worldwide and is characterized by substantial cellular heterogeneity. Even within a single tumor, cancer cells can vary in aggressiveness, while immune,... Read more

Immunology

view channel
Image: The panel expands Cepheid’s respiratory testing portfolio on the GeneXpert platform, offering laboratories greater flexibility in selecting tests based on clinical needs. (Photo courtesy of Cepheid)

Multiplex PCR Test Gains CE Marking to Support Respiratory Infection Diagnosis

Acute respiratory infections often present with overlapping symptoms, making it difficult to distinguish between viral and bacterial causes. Seasonal surges of influenza-like illness in Europe further... Read more

Microbiology

view channel
Image: Malaria is caused by Plasmodium parasites, primarily transmitted through the bites of infected female Anopheles mosquitoes (Image Credit: Adobe Stock)

Complete Malaria Genomes Could Improve Species Identification and Surveillance

Malaria remains a major global health challenge, with an estimated 282 million cases and 610,000 deaths worldwide in 2024. Although most research has focused on Plasmodium falciparum, Plasmodium ovale... Read more

Industry

view channel
Image: The TOMR trial uses Signatera-guided MRD testing to identify high-risk patients for curative-intent treatment.

Natera and Incyte Collaborate on MRD-Guided Colorectal Cancer Treatment Study

Natera (Austin, TX, USA) has entered into a clinical collaboration with Incyte (Wilmington, DE, USA) for a Phase II study evaluating molecular residual disease (MRD)-guided treatment in colorectal cancer.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.