Novel LC-MS/MS Assay Detects Low Creatinine in Sweat and Saliva

By LabMedica International staff writers
Posted on 01 Jan 2025
Print article
Image: The LC-MS/MS assay can serve as a reference method to validate emerging biosensors for renal function monitoring (Photo courtesy of 123RF)
Image: The LC-MS/MS assay can serve as a reference method to validate emerging biosensors for renal function monitoring (Photo courtesy of 123RF)

Timely and accurate monitoring of renal function is essential for managing patients at risk of acute kidney injury (AKI), which affects about 12% of hospitalized patients and up to 57% of ICU patients. In approximately 20% of these cases, the condition progresses to more severe stages of AKI, leading to longer hospital stays, higher mortality rates, and an increased need for invasive renal replacement therapies. Early intervention, driven by frequent or continuous monitoring of renal function biomarkers like creatinine, could potentially delay this progression. As renal failure can advance quickly, frequent venipuncture for creatinine testing is required. Recent advances in microfluidic devices and biosensors have led to the exploration of alternative biofluids, such as sweat and saliva, for non-invasive, continuous monitoring of creatinine. Researchers have now developed a novel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) assay for detecting low creatinine levels in these biofluids.

Researchers at Eindhoven University of Technology (Eindhoven, The Netherlandsl) investigated the correlation between creatinine concentrations in sweat, saliva, and plasma during hemodialysis, with an eye toward future biosensor applications. They measured creatinine levels in sweat, saliva, and plasma from 40 patients undergoing hemodialysis. Using the novel LC-MS/MS assay, they quantified low creatinine concentrations in these biofluids. Correlation analyses were conducted to compare creatinine levels across the biofluids. The LC-MS/MS assay demonstrated excellent accuracy (93.9% to 97.8%) and low imprecision (3.4% to 8.1%) for measuring very low creatinine concentrations, with a limit of quantitation of 1.26 µmol/L.

The study revealed strong correlations between creatinine concentrations in sweat and saliva compared to plasma (ρ: 0.68 and 0.80, respectively). During hemodialysis, creatinine concentrations declined similarly across all three biofluids. These strong correlations suggest that sweat and saliva could serve as reliable, non-invasive alternatives to traditional blood tests for assessing kidney function. This research improves the understanding of creatinine excretion pathways and lays the groundwork for the development of patient-friendly, continuous kidney function monitoring methods, such as wearable biosensors.

New
Gold Member
Strep Pneumoniae Rapid Test
Strep Pneumoniae (6503 – 6573)
New
Gold Member
ZIKA Virus Test
ZIKA ELISA IgG
New
Gold Member
Measles Test
MEASLES ELISA IgG/IgM
New
Chagas Disease Test
Simple/Stick Chagas/WB

Print article

Channels

Microbiology

view channel
Image: The breakthrough system offers a faster way to diagnose bloodborne infections (Photo courtesy of Melio)

Culture-Free Platform Rapidly Identifies Blood Stream Infections

Neonatal sepsis is a life-threatening condition that results from bloodstream infections in newborns under 28 days old. Due to their immature immune systems, newborns are especially vulnerable to infections.... Read more

Pathology

view channel
Image: The AI tool can search through data and histology images for much more precise information on cancer treatment effectiveness (Photo courtesy of Shutterstock)

AI Tool Analyzes 30K Data Points Per Medical Imaging Pixel in Cancer Search

A new artificial intelligence (AI)-powered tool can detect cell-level characteristics of cancer by analyzing data from very small tissue samples, some as tiny as 400 square micrometers, equivalent to the... Read more

Technology

view channel
Image: Human tear film protein sampling methods (Photo courtesy of Clinical Proteomics. 2024 Mar 13;21:23. doi: 10.1186/s12014-024-09475-8)

New Lens Method Analyzes Tears for Early Disease Detection

Bodily fluids, including tears and saliva, carry proteins that are released from different parts of the body. The presence of specific proteins in these biofluids can be a sign of health issues.... Read more

Industry

view channel
Image: The game-changing immunoassay diagnostics platform delivers results from whole blood sample in 10 minutes (Photo courtesy of SpinChip)

bioMérieux Acquires Norwegian Immunoassay Start-Up SpinChip Diagnostics

bioMérieux (Marcy l’Étoile, France) has agreed to acquire SpinChip Diagnostics (Oslo, Norway), the developer of a game-changing immunoassay diagnostics platform. The small benchtop analyzer is well adapted... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.