We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App





Rapid Antigen Tests Detect Omicron, Delta SARS-CoV-2 Variants

By LabMedica International staff writers
Posted on 17 Oct 2022
Print article
Image: The BD Veritor System for Rapid Detection of SARS‑CoV‑2 antigen test detects nucleoproteins from the SARS‑CoV‑2 virus in as little as 15 minutes, and can be conducted at the point-of-care (Photo courtesy of Becton, Dickinson and Company)
Image: The BD Veritor System for Rapid Detection of SARS‑CoV‑2 antigen test detects nucleoproteins from the SARS‑CoV‑2 virus in as little as 15 minutes, and can be conducted at the point-of-care (Photo courtesy of Becton, Dickinson and Company)

Accurate and accessible testing for SARS-CoV-2 is a critical tool for the timely identification of infection to inform isolation recommendations, prevent transmission, and facilitate early initiation of therapy to reduce disease progression.

Rapid antigen tests for COVID-19 show great promise as a testing method that is easy to use, accessible, and cost-effective Rapid antigen tests (Ag-RDTs) have lower sensitivity than RT-PCR tests for detecting SARS-CoV-2, however, sensitivity can be improved through serial testing.

A large team of medical scientists at the University of Massachusetts Chan Medical School, Worcester, MA, USA) compared the performance of Ag-RDTs in detecting the Delta (B.1.617.2) and Omicron (B.1.1.529) variants of SARS-CoV-2. The team relied on data from the prospective cohort study Test Us At Home in which participants serially took both at-home antigen and send-in PCR COVID-19 tests over a period of 10 to 15 days. This analysis focuses on the 5,779 individuals who tested negative for SARS-CoV-2 at the start of the parent study and the 207 individuals of those who later tested positive for the virus by PCR.

On enrollment, participants were assigned to 1 of 3 Ag-RDTs with emergency use authorization: BD Veritor At-Home COVID-19 Test (Becton, Dickinson and Company, San Diego, CA, USA), Quidel QuickVue At-Home OTC COVID-19 Test (San Diego, CA, USA) and Abbott BinaxNOW COVID-19 Antigen Self-Test (Princeton, NJ, USA). Participants received the Ag-RDT and the Quest Diagnostics collection kit for COVID-19 by mail at the shipping address provided on enrollment.

The investigators reported that a total of 207 participants were positive on RT-PCR (58 Delta, 149 Omicron). Differences in sensitivity between variants were not statistically significant (same day: Delta, 15.5% [95% CI, 6.2% to 24.8%] versus Omicron, 22.1% [CI, 15.5% to 28.8%]; at 48 hours: Delta, 44.8% [CI, 32.0% to 57.6%] versus Omicron, 49.7% [CI, 41.6% to 57.6%]). Among 109 participants who had RT-PCR–positive results for 48 hours, rapid antigen sensitivity did not differ significantly between Delta- and Omicron-infected participants (48-hour sensitivity: Delta, 81.5% [CI, 66.8% to 96.1%] versus Omicron, 78.0% [CI, 69.1% to 87.0%]). Only 7.2% of the 69 participants with RT-PCR–positive results for shorter than 48 hours tested positive by Ag-RDT within one week; those with Delta infections remained consistently negative on Ag-RDTs.

The authors concluded that nasal swab Ag-RDT performance was similar between the Omicron and Delta variants. In both cases, detection of virus with Ag-RDTs was associated with relative viral load as measured by Ct value. The data suggest that serial testing continues to be important in improving the performance of Ag-RDTs. Future work to increase the understanding of persons with singleton RT-PCR positivity is needed to determine the public health significance of a false-negative Ag-RDT result in this subpopulation. The study was published on October 11, 2022 in the journal Annals of Internal Medicine.

Related Links:
University of Massachusetts Chan Medical School
Becton, Dickinson and Company
Quidel 
Abbott 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The real-time multiplex PCR test is set to revolutionize early sepsis detection (Photo courtesy of Shutterstock)

1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens

Sepsis contributes to one in every three hospital deaths in the US, and globally, septic shock carries a mortality rate of 30-40%. Diagnosing sepsis early is challenging due to its non-specific symptoms... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.