We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Olympus

Manufactures optical and digital equipment for the healthcare and consumer electronics sectors, including endoscopy a... read more Featured Products: More products

Download Mobile App




Osteopontin and Osteoprotegerin Investigated In Peripheral Artery Disease

By LabMedica International staff writers
Posted on 08 Sep 2022
Print article
mage: The AU560 automatic enzymatic analyzer (Photo courtesy of Sysmed Lab Europe)
mage: The AU560 automatic enzymatic analyzer (Photo courtesy of Sysmed Lab Europe)

Peripheral artery disease (PAD) is one of the many complications of systemic atherosclerosis and it is accompanied by high rates of cardiovascular diseases (CVD) morbidity and mortality. PAD is a common condition in which narrowed arteries reduce blood flow to the arms or legs.

Atherosclerosis is a complex procedure of different pathways. Among other cytokines, inflammation and calcification are known to be regulated also by well-known bone regulators, such as osteoprotegerin (OPG) and osteopontin (OPN). OPG is a secretory basic glycoprotein and a member of the tumor necrosis factor (TNF) receptor superfamily, acting as an inhibitor of bone resorption. OPN is a highly phosphorylated glycophosphoprotein having acidic characteristics and rich in aspartic acid.

Clinical Scientists at the Medical School University of Cyprus (Nicosia, Cyprus) and their colleagues enrolled 203 consecutive patients with symptomatic, established PAD requiring endovascular revascularization (percutaneous transluminal angioplasty–PTA and/or stent placement) of any or both of their lower limbs (PAD group–PADG). They also recruited 78 age- and sex-matched subjects with less than two classical cardiovascular risk factors (hypertension, diabetes, hyperlipidemia, smoking, family history of premature CAD) who served as control group (COG).

Overnight fasting, blood samples were obtained and glycemic and lipid parameters were immediately assayed in an AU560 automatic enzymatic analyzer (Olympus, Hamburg, Germany). The glycated hemoglobin (HbA1c) was determined by high-performance liquid chromatography (Menarini Diagnostics, Florence, Italy) only in diabetic patients. Serum OPN and OPG were assayed using quantikine immunoassay EIA kits (R&D Systems Inc., Minneapolis, MN, USA) and Metra, San Diego, CA, USA). The high-sensitivity C-Reactive Protein (hsCRP) levels were measured with latex-enhanced immunonephelometry (Dade Behring, Marburg, Germany).

The investigators reported that during 12-month follow-up, 82 major adverse cardiovascular events (MACE) were recorded (MACE subgroup). The rest of 124 PAD patients remained free of MACE (non-MACE subgroup). At baseline, OPG (9.89 ± 2.85 ng/mL versus 3.47 ± 1.95 ng/mL) and OPN (79.99 ± 38.29 ng/mL versus 35.21 ± 14.84 ng/mL) levels were significantly higher in PADG compared to COG, as well as in MACE subgroup compared to non-MACE subgroup (13.29 ± 3.23 ng/mL versus 10.86 ± 3 ng/mL and 96.45 ± 40.12 ng/mL versus 78.1 ± 38.29 ng/mL, respectively). An independent association of PAD with OPG and OPN was found in the whole patient cohort.

The authors concluded that baseline high OPG and OPN levels were independently associated with the presence of PAD. Even higher levels of those biomarkers were detected among PAD patients with MACE. The study was published on September 1, 2022 in the journal Cardiovascular Diabetology.

Related Links:
Medical School University of Cyprus
Olympus 
Menarini Diagnostics 
R&D Systems Inc 
Metra 
Dade Behring 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.