We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

BECKMAN COULTER, INC.

Beckman Coulter develops, manufactures and markets laboratory systems, reagents, centrifugation, lab automation, elec... read more Featured Products: More products

Download Mobile App




Faster Method Diagnoses Pediatric Urinary Tract Infections

By LabMedica International staff writers
Posted on 01 Aug 2022
Print article
Image: The iQ200 series automated urine microscopy analyzer produces shortened TAT with standardized results (Photo courtesy of Beckman Coulter)
Image: The iQ200 series automated urine microscopy analyzer produces shortened TAT with standardized results (Photo courtesy of Beckman Coulter)

Urinary tract infections (UTIs) affect the urinary tract, including the bladder (cystitis), urethra (urethritis) or kidneys (kidney infection). UTIs may be treated with antibiotics, but they're not always needed.

UTIs are common in children and when left untreated can cause acute distress, septic shock, and even kidney damage. The gold standard for diagnosing the condition, urine culture, is slow and labor-intensive for laboratory staff, leading doctors to sometimes prescribe antibiotics inappropriately before getting results, thus contributing to the rise of antibiotic resistance.

Biomedical Scientists at the Nationwide Children's Hospital (Columbus, OH, USA) investigated the association between urinalysis results and those of concurrent urine cultures, and to assess the accuracy of a published prediction model for the results of urine culture in a pediatric population. The study was a retrospective chart review of 5,535 children who previously underwent both urinalysis and urine culture for UTI and carried out at the hospital from January 2019 to December 2020. The study population had a median age of 7 years (mean = 9), was 69% female, and of those with positive urine cultures, 85.2% were female.

Dipstick and microscopic sediment urinalysis were performed on an iQ200 Automated Urine Microscopy Analyzer (Beckman Coulter, Brea, CA, USA). Positive urine culture was defined as ≥50,000 colony-forming units/mL of a urinary pathogen. To evaluate their method's performance in children, the team used it to analyze data from the medical records of the children, they entered their age, sex, risk for UTI, and urinalysis results into their test's algorithm to see how accurately it predicted their urine culture results. Six variables were selected for the prediction model UTOPIA equation: ×1:age UTI risk, ×2:sex, ×3:nitrite, ×4:leukocyte esterase (LE), ×5:white blood cell count (WBC) and ×6:grade of bacteria with ×2-×4 and ×6 being categorical.

The investigators reported that the UTOPIA value exhibited an area under the ROC curve value of 0.825, which is significantly higher (P<0.001) than the individual components for ages 0.546 (0.52-0.57), sex 0.575 (0.56-0.59) nitrite 0.618 (0.60-0.63), LE 0.757 (0.74-0.78), the grade of bacteria 0.664 (0.64-0.69), and the WBC count 0.776 (0.75-0.80). The closer the ROC value was to 1, the more accurate the testing strategy.

Jingcai Wang, MD, PhD, CC(NRCC), SH(ASCP)MLS, a Certified Medical Laboratory Scientist and senior author of the study, said, “The test represents a simple way to predict urine culture results. It can potentially reduce unnecessary urine cultures, save money, and reduce use of unnecessary antibiotics in children.”

The authors concluded that the predictive model UTOPIA value demonstrated good diagnostic performance for predicting urine culture results and possibly reducing unnecessary urine culture and antibiotic use in a retrospective pediatric population. The study was presented on July 27, 2022 at the AACC 2022 meeting held in Chicago, IL, USA.

Related Links:
Nationwide Children's Hospital
Beckman Coulter 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The real-time multiplex PCR test is set to revolutionize early sepsis detection (Photo courtesy of Shutterstock)

1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens

Sepsis contributes to one in every three hospital deaths in the US, and globally, septic shock carries a mortality rate of 30-40%. Diagnosing sepsis early is challenging due to its non-specific symptoms... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.