We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Albumin-Related Ratios Investigated in HBV-Associated Decompensated Cirrhosis

By LabMedica International staff writers
Posted on 25 Mar 2022
Print article
Image: Liver biopsy: High magnification photomicrograph of ground glass hepatocytes, as seen in a chronic hepatitis B infection with a high viral load (Photo courtesy of Nephron)
Image: Liver biopsy: High magnification photomicrograph of ground glass hepatocytes, as seen in a chronic hepatitis B infection with a high viral load (Photo courtesy of Nephron)

Decompensated cirrhosis (DeCi) is a terminal liver disease characterized by various complications and associated with dramatically reduced survival. Liver transplantation is the most effective therapy for hepatitis B virus (HBV)-DeCi.

Serum albumin is considered a biomarker of malnutrition–inflammation syndrome, and there is emerging data that hypoalbuminemia is related to worse survival in intensive care unit patients. Albumin has multiple functions and plays important roles in liver disease severity, progression, and prognosis.

Clinical Laboratorians at The Second Affiliated Hospital Zhejiang University (Zhengzhou, China) enrolled a total of 161 HBV-DeCi patients. The main causes of admission were ascites (n = 120, 74.5%), gastrointestinal bleeding (n = 36, 22.5%), hepatorenal syndrome (n = 22, 14.0%), and encephalopathy (n = 10, 6.2%). Twenty-four patients (15.0%) had more than one feature of decompensation at presentation.

Laboratory variables (total bilirubin, total protein, albumin, blood urea nitrogen [BUN], creatinine, aspartate aminotransferase, alanine aminotransferase, C-reactive protein [CRP], white blood count [WBC], platelet count, hemoglobin, neutrophil count, plasma D-dimer, and international normalized ratio [INR]), and HBV-DNA levels, as well as hepatitis B e antigen status, were recorded at admission. Severity of liver disease and prognosis were assessed using the Model for End-Stage Liver Disease (MELD) score.

The investigators reported that a total of 29 (18.0%) patients had died 30 days after admission. The prognostic roles of C-reactive protein-to-albumin ratio (CAR), D-dimer-to-albumin ratio (DAR), prothrombin time-international normalized ratio-to-albumin ratio (PTAR), neutrophil count-to-albumin (NAR), and blood urea nitrogen-to-albumin ratio (BAR) in HBV-DeCi were different. CAR, PTAR, NAR, and BAR were significantly higher in non-survivors compared with survivors. However, DAR did not differ between the two groups. The predictive power of BAR was superior to that of the other four albumin-related biomarkers and similar to that of MELD score. On multivariate analysis, BAR and MELD score were identified as independent prognostic factors, and the combination of BAR and MELD score may improve the prognostic accuracy in HBV-DeCi.

The authors concluded that they had evaluated five albumin-related ratios (CAR, DAR, PTAR, NAR, and BAR) for the prediction of mortality in HBV-DeCi patients. Their study suggests that BAR can be a simple, effective, and useful prognostic tool to predict poor outcomes in HBV-DeCi patients and that use of a combination of BAR and MELD score can improve the prognostic accuracy. The study was published on March 17, 2022 in the Journal of Clinical Laboratory Analysis.

Related Links:
The Second Affiliated Hospital Zhejiang University 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.