We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

QIAGEN

Qiagen is a provider of sample and assay technologies for molecular diagnostics and applied testing, including comple... read more Featured Products: More products

Download Mobile App




Events

09 Apr 2024 - 12 Apr 2024
15 Apr 2024 - 17 Apr 2024
23 Apr 2024 - 26 Apr 2024

Clinical Application of Leukocyte Counts Based on Targeted DNA Methylation Analysis

By LabMedica International staff writers
Posted on 14 Mar 2022
Print article
Image: PyroMark Q96 ID instrument for quantitative analysis of genetic or epigenetic DNA modifications using Pyrosequencing technology (Photo courtesy of Karolinska Institutet)
Image: PyroMark Q96 ID instrument for quantitative analysis of genetic or epigenetic DNA modifications using Pyrosequencing technology (Photo courtesy of Karolinska Institutet)

Leukocyte subsets are usually quantified with automated cell counting devices and particularly for stratification of lymphocyte subsets with flow cytometry. Despite broad application, conventional methods have several limitations.

DNA methylation (DNAm) is a covalent modification of cytosine residues, mostly at CG dinucleotides (CpG sites). By measuring the methylation level at CpG sites with cell-type–specific hypo- or hypermethylation, it is possible to quantify the composition of leukocyte subsets using statistical algorithms (deconvolution models).

Biomedical Engineers at the RWTH Aachen University (Aachen, Germany) and colleagues optimized and validated targeted DNAm assays for leukocyte deconvolution using 332 venous and 122 capillary blood samples from healthy donors. In addition, they tested 36 samples from ring trials and venous blood from 266 patients diagnosed with different hematological diseases. Deconvolution of cell types was determined with various models using DNAm values obtained by pyrosequencing or digital droplet PCR (ddPCR).

DNA was isolated from 150 µL venous or 50 µL capillary blood and bisulfite-treated with the EZ DNA Methylation Kit (Zymo Research, Irvine, CA, USA). PCR amplicons were sequenced on a PyroMark Q96 ID (Qiagen, Hilden, Germany) and analyzed with Qiagen’s PyroMark Q96 CpG 1.0.9. Digital Droplet Polymerase Chain Reaction (ddPCR) was carried out with the QX200 Droplet Digital reader (Bio-Rad, Hercules, CA, USA). Absolute leukocyte quantification by pyrosequencing was also performed.

The investigators reported that relative leukocyte quantification correlated with conventional blood counts for granulocytes, lymphocytes, B cells, T cells (CD4 or CD8), natural killer cells, and monocytes with pyrosequencing and ddPCR measurements. In some patients, particularly with hematopoietic malignancies, they observed outliers in epigenetic leukocyte counts, which could be discerned if relative proportions of leukocyte subsets did not sum up to 100%. Furthermore, absolute quantification was obtained by spiking blood samples with a reference plasmid of known copy number. The results confirmed cell-type–specific hypomethylation in the genes WDR20, CD4, CD8A, WIPI2, SLC15A4, and CENPA, which was more pronounced compared to the Illumina BeadChip data or reverse nonnegative least square (NNLS) estimation.

The authors concluded that targeted DNAm analysis by pyrosequencing or ddPCR is a valid alternative to quantify leukocyte subsets, but some assays require further optimization. The study was published on February 14, 2022 in the journal Clinical Chemistry.

Related Links:
RWTH Aachen University 
Zymo Research 
Qiagen 
Bio-Rad 

 

 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
One Step HbA1c Measuring System
GREENCARE A1c
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: The cobas Malaria test is the first FDA-approved molecular test to screen U.S. blood donors for malaria (Photo courtesy of Roche)

First FDA-Approved Molecular Test to Screen Blood Donors for Malaria Could Improve Patient Safety

Malaria, a serious illness that often leads to death, is spread by a specific mosquito species that infect humans with a parasite. Other transmission modes include blood transfusions, organ transplants,... Read more

Pathology

view channel
Image: The medical office procedure detects the key biomarker in Parkinson’s and related neurodegenerative diseases (Photo courtesy of BIDMC)

Simple Skin Biopsy Test Detects Parkinson’s and Related Neurodegenerative Diseases

Parkinson's disease and a group of related neurodegenerative disorders known as synucleinopathies impact millions globally. These conditions, including Parkinson’s disease (PD), dementia with Lewy bodies... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.