We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
GLOBETECH PUBLISHING LLC

QIAGEN

Qiagen is a provider of sample and assay technologies for molecular diagnostics and applied testing, including comple... read more Featured Products: More products

Download Mobile App




Events

ATTENTION: Due to the COVID-19 PANDEMIC, many events are being rescheduled for a later date, converted into virtual venues, or altogether cancelled. Please check with the event organizer or website prior to planning for any forthcoming event.

Clinical Application of Leukocyte Counts Based on Targeted DNA Methylation Analysis

By LabMedica International staff writers
Posted on 14 Mar 2022
Print article
Image: PyroMark Q96 ID instrument for quantitative analysis of genetic or epigenetic DNA modifications using Pyrosequencing technology (Photo courtesy of Karolinska Institutet)
Image: PyroMark Q96 ID instrument for quantitative analysis of genetic or epigenetic DNA modifications using Pyrosequencing technology (Photo courtesy of Karolinska Institutet)

Leukocyte subsets are usually quantified with automated cell counting devices and particularly for stratification of lymphocyte subsets with flow cytometry. Despite broad application, conventional methods have several limitations.

DNA methylation (DNAm) is a covalent modification of cytosine residues, mostly at CG dinucleotides (CpG sites). By measuring the methylation level at CpG sites with cell-type–specific hypo- or hypermethylation, it is possible to quantify the composition of leukocyte subsets using statistical algorithms (deconvolution models).

Biomedical Engineers at the RWTH Aachen University (Aachen, Germany) and colleagues optimized and validated targeted DNAm assays for leukocyte deconvolution using 332 venous and 122 capillary blood samples from healthy donors. In addition, they tested 36 samples from ring trials and venous blood from 266 patients diagnosed with different hematological diseases. Deconvolution of cell types was determined with various models using DNAm values obtained by pyrosequencing or digital droplet PCR (ddPCR).

DNA was isolated from 150 µL venous or 50 µL capillary blood and bisulfite-treated with the EZ DNA Methylation Kit (Zymo Research, Irvine, CA, USA). PCR amplicons were sequenced on a PyroMark Q96 ID (Qiagen, Hilden, Germany) and analyzed with Qiagen’s PyroMark Q96 CpG 1.0.9. Digital Droplet Polymerase Chain Reaction (ddPCR) was carried out with the QX200 Droplet Digital reader (Bio-Rad, Hercules, CA, USA). Absolute leukocyte quantification by pyrosequencing was also performed.

The investigators reported that relative leukocyte quantification correlated with conventional blood counts for granulocytes, lymphocytes, B cells, T cells (CD4 or CD8), natural killer cells, and monocytes with pyrosequencing and ddPCR measurements. In some patients, particularly with hematopoietic malignancies, they observed outliers in epigenetic leukocyte counts, which could be discerned if relative proportions of leukocyte subsets did not sum up to 100%. Furthermore, absolute quantification was obtained by spiking blood samples with a reference plasmid of known copy number. The results confirmed cell-type–specific hypomethylation in the genes WDR20, CD4, CD8A, WIPI2, SLC15A4, and CENPA, which was more pronounced compared to the Illumina BeadChip data or reverse nonnegative least square (NNLS) estimation.

The authors concluded that targeted DNAm analysis by pyrosequencing or ddPCR is a valid alternative to quantify leukocyte subsets, but some assays require further optimization. The study was published on February 14, 2022 in the journal Clinical Chemistry.

Related Links:
RWTH Aachen University 
Zymo Research 
Qiagen 
Bio-Rad 

 

 

Automated ELISA-IFA-BLOT Processor AP 22
Gold Supplier
Quality Control Material
Multichem U
New
Automated Hematology Analyzer
Celltac Alpha MEK-1301/1302
New
Microbial Infections In-Vitro Diagnostic Solution
Weezion dx

Print article

Channels

Molecular Diagnostics

view channel
Image: A new method reliably detects protein changes in blood that are typical of Parkinson`s disease (Photo courtesy of Pexels)

First-Ever Blood Test Detects Parkinson’s Disease

Until now, the diagnosis of Parkinson's disease has been based primarily on typical movement disorders such as muscle stiffness, slower movements and shaking. However, the disease starts up to 20 years... Read more

Industry

view channel
Image: Fujirebio has acquired ADx NeuroSciences for 40 million Euros (Photo courtesy of Pexels)

Fujirebio Acquires ADx NeuroSciences to Speed Development of Neurodegenerative Diseases Diagnostic Tests

Fujirebio Holdings, Inc. (Tokyo, Japan) has announced the acquisition of ADx NeuroSciences (Gent, Belgium) for EUR 40 million in a deal that is expected to close in July 2022, pending the satisfaction... Read more
Copyright © 2000-2022 Globetech Media. All rights reserved.