We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

Download Mobile App




Next-Generation Sequencing Strategy Validated for MRD Monitoring in Multiple Myeloma

By LabMedica International staff writers
Posted on 18 Nov 2021
Print article
Image: The LymphoTrack Assay kits are designed for the identification of gene rearrangements in hematologic samples utilizing NGS technologies (Photo courtesy of Invivoscribe)
Image: The LymphoTrack Assay kits are designed for the identification of gene rearrangements in hematologic samples utilizing NGS technologies (Photo courtesy of Invivoscribe)
Multiple myeloma (MM) is a plasma-cell dyscrasia characterized by the accumulation of plasma cells in the bone marrow that produces an excess of clonal immunoglobulins (M-protein or monoclonal component).

The presence of low levels of drug-resistant cells (known as minimal residual disease, MRD) that remain undetected by conventional serologic and morphologic methods explains frequent relapses with this disease, which is still considered an incurable illness.

Hematologists at the University Hospital of Salamanca (Salamanca, Spain) and their colleagues standardized the performance of the LymphoTrack next-generation sequencing (NGS) assays (Invivoscribe, San Diego, CA, USA), targeting clonal immunoglobulin rearrangements, in order to reproduce the detection of tumor clonotypes and MRD quantitation in myeloma. The quantification ability of the assay was evaluated through serial dilution investigations. Paired samples from 101 patients were tested by LymphoTrack, using Sanger sequencing and a next-generation flow (NGF) assay (EuroFlow, Leiden, The Netherlands) as validated references for diagnostic and follow-up evaluation, respectively. MRD studies using LymphoTrack were performed in parallel at two laboratories to evaluate reproducibility.

The investigators set the sensitivity as 1.3 tumor cells per total number of input cells. Clonality was confirmed in 99% and 100% of cases with Sanger and NGS, respectively, showing great concordance (97.9%), although several samples had minor discordances in the nucleotide sequence of rearrangements. Parallel NGS was performed in 82 follow-up cases, achieving a median sensitivity of 0.001%, while for NGF, median sensitivity was 0.0002%. Reproducibility of LymphoTrack-based MRD studies (85.4%) and correlation with NGF (R2 > 0.8) were high. Bland-Altman tests showed highly significant levels of agreement between flow and sequencing.

The authors concluded that altogether, their findings support the usefulness of alternative NGS approaches in MM, demonstrating a statistically significant level of agreement with previously validated methods routinely used for clonality detection and MRD assessment, and underline the need for further standardization of quantitation procedures of the LymphoTrack assay for use as a suitable alternative to the ClonoSEQ assay (Adaptive Technologies, Seattle, WA, USA). The study was published on October 7, 2021 in the journal Archives of Pathology and Laboratory Medicine.

Related Links:
University Hospital of Salamanca
Invivoscribe
EuroFlow
Adaptive Technologies


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.