We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App





Rapid Olfactory Test Shows Potential as Screening Tool for COVID-19

By LabMedica International staff writers
Posted on 20 Jul 2021
Print article
Illustration
Illustration
A study that evaluated the feasibility of a novel, objective olfactory test as part of an initial screening for COVID-19 in adults with unknown disease status has concluded that olfactory dysfunction (OD) is one of the earliest and strongest predictors of COVID-19 infection, and thus is promising as a disease screening tool.

In the prospective, cross-sectional study, researchers at University of California, San Diego (La Jolla, CA, USA) enrolled healthy adults (aged ≥ 18 years) from a single college campus COVID-19 screening site. Participants were screened for OD using a novel scent card (SAFER Diagnostics) followed immediately by polymerase chain reaction (PCR) testing for SARS-CoV-2 from nasopharyngeal swabs. The SAFER card contained a single scent in a scratch-and-sniff label that the participant identified from 8 answer options: lemon, grape, floral, blueberry, banana, mint, unsure, or no scent. Answers were processed electronically via a QR code. An incorrect choice was classified as OD. Participant demographics, medical history, COVID-19 symptoms, and subjective smell function on a binary and 10-point visual analog scale (VAS, with 0 indicating no sense of smell and 10 indicating normal sense of smell) were also collected.

A total of 163 participants were prospectively screened for OD using the scent card followed by SARS-CoV-2 PCR testing. Of those who tested PCR-positive for COVID-19, 75% (12 out of 16) failed olfactory screening compared with 4.8% (7 out of 147) among those testing PCR-negative for COVID-19. The sensitivity, specificity, positive predictive value, and negative predictive value of the scent card in detecting those with COVID-19 were 75.0%, 95.2%, 63.2%, and 97.2%, respectively. Including the symptom fatigue along with OD achieved 93.8% sensitivity and 89.8% specificity in disease screening. The addition of fever and cough did not further increase sensitivity.

While only 37.5% (6 out of 16) of COVID-19 test-positive participants reported subjective anosmia, 75% failed screening with the scent card. A failed scent card screen was the greatest predictor of COVID-19 positivity (odds ratio [OR], 80.24; 95% CI, 14.77-435.90) when compared with other symptoms including cough, fever, fatigue, and a history of COVID-19 exposure. Thus, the study demonstrated that a rapid psychophysical olfaction test is feasible as a screening tool for COVID-19.

Related Links:
University of California, San Diego

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
HLX
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
SARS-CoV-2 RT-PCR Assay
Reliance SARS-CoV-2 RT-PCR Assay Kit

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.