We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

BIO-RAD LABORATORIES

Provides full range of instrumentation, reagent kits, software and quality control systems to clinical laboratories. ... read more Featured Products: More products

Download Mobile App




Diabetic Biomarkers Concordance Compared in South African Blacks

By LabMedica International staff writers
Posted on 28 Jun 2021
Print article
Image: The D-10 Hemoglobin Testing System provides comprehensive, automated hemoglobin testing in a compact footprint, combining HbA1c and HbA2/F/A1c testing on a single platform (Photo courtesy of Bio-Rad)
Image: The D-10 Hemoglobin Testing System provides comprehensive, automated hemoglobin testing in a compact footprint, combining HbA1c and HbA2/F/A1c testing on a single platform (Photo courtesy of Bio-Rad)
Sub-Saharan Africa is projected to experience a significant increase in the prevalence of diabetes mellitus by in the near future and accurate, comparable prevalence estimates will be essential to planning and monitoring by public health authorities.

Diagnosis based on glycated hemoglobin (HbA1c) is attractive because it provides an integrated assessment of glycemic status over the preceding three months and has low analytical variability, but the extent to which this single threshold may be adopted in all sub-Saharan African populations is questionable. Existing data suggest that in individuals of African descent, HbA1c may be higher for any given degree of glycaemia than in individuals of European descent.

A large international team of medical scientists led by those at the University of the Witwatersrand (Johannesburg, South Africa) included in a study 765 black individuals aged 40–70 years and with no history of diabetes. The team investigated concordance between hemoglobin A1c (HbA1c)-defined diabetes and fasting plasma glucose (FPG)-defined diabetes in a black South African population with a high prevalence of obesity.

Capillary blood samples were tested for hemoglobin at point of collection using the Haemocue Hb 201+analyser (Haemocue, Ängelholm, Sweden). Whole blood was analyzed for HbA1c using high-performance liquid chromatography on the Bio-Rad D-10 (Bio-Rad Laboratories, Hercules, CA, USA) with a reportable range of 3.8%–18.5%. Plasma was analyzed for glucose using colorimetric methods on the Randox Plus clinical chemistry analyzer (Randox, Crumlin, UK) with a range of 0.36–35 mmol/L. Serum insulin assays were performed on the Immulite 1000 chemistry analysis system (Siemens Healthineers, Erlangen, Germany), using a solid-phase, enzyme-labeled chemiluminescent immunometric assay (range 2–300 μIU/mL).

The investigators reported that the prevalence of HbA1c-defined diabetes was four times the prevalence of FPG-defined diabetes (17.5% versus 4.2%). Classification was discordant in 15.7% of participants, with 111 individuals (14.5%) having HbA1c-only diabetes. Median body mass index, waist and hip circumference, waist-to-hip ratio, subcutaneous adipose tissue and Homoeostatic Model Assessment of Insulin Resistance (HOMA-IR) in participants with HbA1c-only diabetes were similar to those in participants who were normoglycemic by both biomarkers and significantly lower than in participants with diabetes by both biomarkers. HOMA-IR and fat distribution explained additional HbA1c variance beyond glucose and age only in women.

The authors concluded that concordance was poor between HbA1c and FPG in diagnosis of diabetes in black South Africans, and participants with HbA1c-only diabetes phenotypically resembled normoglycemic participants. Further work is necessary to determine which of these parameters better predicts diabetes-related morbidities in this population and whether a population-specific HbA1c threshold is necessary. The study was published on June 17, 2021 in the journal BMJ OPEN.

Related Links:
University of the Witwatersrand
Haemocue
Bio-Rad Laboratories
Randox
Siemens Healthineers


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.