We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

BECKMAN COULTER, INC.

Beckman Coulter develops, manufactures and markets laboratory systems, reagents, centrifugation, lab automation, elec... read more Featured Products: More products

Download Mobile App




Innate Lymphoid Cells Analyzed at the Maternal-Fetal Interface

By LabMedica International staff writers
Posted on 26 May 2021
Print article
Image: The Beckman Coulter AcT Diff automatic cell counter (Photo courtesy of Beckman Coulter)
Image: The Beckman Coulter AcT Diff automatic cell counter (Photo courtesy of Beckman Coulter)
Preterm birth (PTB) is one of the major causes of neonatal morbidity and mortality worldwide. It is commonly accepted that the act of giving birth is the final step in a proinflammatory signaling cascade, orchestrated by an intrauterine milieu coupled to hormonal cues.

The gestational period is comprised of decidualization, placentation and fetal development and requires uterine quiescence and the production of both anti- and proinflammatory cytokines from maternal and fetal cells. Throughout pregnancy, three distinct biological periods characterized by different immunological microenvironments occur.

A team of Medical Scientists at the University of Coimbra (Coimbra, Portugal) analyzed 15 full-term delivery samples and six preterm delivery samples (PTB). In the full-term group (FTB) peripheral blood was taken during routine blood analysis, on three occasions: 1st, 2nd and 3rd trimester. After delivery, peripheral blood, cord blood and placenta were collected. In the PTB group, peripheral blood samples were obtained on two occasions: before and 24 hours after treatment with progesterone.

The team dissected the placenta and the decidual tissue and lymphocytes were isolated from the decidua basalis and adjacent tissue (villi). Cells were counted on a Beckman Coulter AcT Diff automatic cell counter (Beckman Coulter, Brea, CA, USA) and isolated lymphocytes was placed in a cytometry tube and labeled with primary antibodies. Stained samples were acquired on a BD FACS Canto II flow cytometer (BD Biosciences, San Jose, CA, USA) Interleukin 17 (IL-17), IL-22, interferon gamma (IFN-γ) and IL-4 were determined by ELISA kits (Biolegend Legend Max, San Diego, CA, USA) and read on a Bio-Rad model 600 microplate reader (Bio-Rad, Hercules, CA, USA).

The investigators observed significantly increased relative frequencies of innate lymphoid cells 2 (ILC2) and ILC3 in the decidua, as well as an increase of ILC2 in cord blood samples in PTB group, compared to FTB samples. They also found a decrease in IFN-γ in peripheral blood samples of the PTB group, suggesting a functional withdrawal. Additionally, IL-4, IL-17, IL-22 levels were similar in PTB and FTB groups, denoting a relevant role in mediating labor.

The authors concluded that labor might be characterized by decreased tissue remodeling and repair functions, accompanied by a marked inflammatory response, due to high levels of ILC2 and ILC3. Also, the ELISA studies propose that labor might be characterized by a functional IFN- γ withdrawal. However, there was no significant decline in ILC1 population that could account for this result. The study was published on May 6, 2021 in the journal BMC Immunology.

Related Links:
University of Coimbra
Beckman Coulter
BD Biosciences
Biolegend Legend
Bio-Rad


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.