Automated Urine Microscope Verified for Regional Laboratories

By LabMedica International staff writers
Posted on 03 Feb 2021
Print article
Image: The UriSed 3 PRO is a professional automated urine sediment analyzer with a revolutionary new optical system combining bright-field and phase contrast microscopy (Photo courtesy of 77 Elektronika)
Image: The UriSed 3 PRO is a professional automated urine sediment analyzer with a revolutionary new optical system combining bright-field and phase contrast microscopy (Photo courtesy of 77 Elektronika)
Automated Urine Microscopy examines a sample of urine under a microscope. It can check cells from the urinary tract, blood cells, crystals, bacteria, parasites, and cells from tumors. This test is often used to confirm the findings of other tests or add information to a diagnosis.

Automation of urine particle counting has become a clinical standard in medium-sized and large laboratories by means of flow cytometry or several types of image analyzers. Reliable implementation of those instruments requires utilization of reference procedures in their verification.

Clinical Chemists and Microbiologists from Helsinki University Hospital (Helsinki, Finland) carried out the primary verification with 463 urine specimens, and against urine culture on chromogenic agar plates with 396 parallel specimens. Nine secondary instruments were compared pairwise with the primary instrument. Both mid-stream collections (generally 90% of all specimens) and catheterized specimens were taken into the study, based on particle findings.

Specimens were chosen from routine analysis by UF-1000i instrument (Sysmex, Kobe, Japan) for verification of the primary (“Gold”) UriSed 3 PRO instrument (77 Elektronika, Budapest, Hungary) against reference visual microscopy during a 6-week period in September - October 2018. Comparisons to urine culture results were available for 396 parallel samples which were cultured by using automated inoculation with 1 µL loop (WASP automated microbiology instrument, COPAN Wasp, Brescia, Italy) on chromogenic agar plates (CHROMagar Orientation medium, CHROMagar, Paris, France) following incubation at 35 °C for 18 hours.

The scientists reported that relative imprecisions compared to Poisson distribution, R(CV), were estimated to be 1.0 for white blood cell (WBC) and 1.5 for red blood cell (RBC) counts, respectively. Spearman’s correlations against visual microscopy were rS = 0.94 for WBC, rS = 0.87 for RBC, and rS = 0.82 for squamous epithelial cell (SEC) counts. Agreement with visual microscopy (Cohen’s weighted kappa) was 0.94 for WBC, 0.89 for RBC, 0.88 for SEC, 0.59 for combined casts, and 0.49 for non-squamous epithelial cells (NEC). Bacteria were detected with a sensitivity of 90% and specificity of 39 against culture at 107 colony forming bacteria/L (CFB/L = 104 CFU/mL). Created flagging limits allowed automated reporting for 70-75 % of patient results.

The authors were able to install 10 UriSed 3 PRO instruments in a regional laboratory environment at HUSLAB, providing about 160,000 automated particle counts annually at 24/7 basis, thus satisfying both routine testing and emergency analysis of clinical samples. Analytical performance fulfilled the analytical performance specifications and expectations obtained from preliminary testing. The study was published on January 26, 2021 in the journal Clinica Chimica Acta.

Related Links:
Helsinki University Hospital
Sysmex
77 Elektronika
COPAN Wasp
CHROMagar

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Specimen Collection & Transport
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.