We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

BMG LABTECH

BMG LABTECH is a manufacturer of a wide range of dedicated and multi-mode microplate instruments ranging from single-... read more Featured Products: More products

Download Mobile App




Combination Urinary Biomarker Panel Detects Pancreatic Cancer Earlier

By LabMedica International staff writers
Posted on 11 Jan 2021
Print article
Image: The FLUOstar Omega Microplate Reader (Photo courtesy of BMG LABTECH).
Image: The FLUOstar Omega Microplate Reader (Photo courtesy of BMG LABTECH).
Pancreatic ductal adenocarcinoma (PDAC) is one of the deadliest cancers, with only around 9% of patients surviving more than 5 years. Asymptomatic in its initial stages, PDAC is mostly diagnosed late, when already a locally advanced or metastatic disease, as there are no useful biomarkers for detection in its early stages, when surgery can be curative.

While blood has traditionally been the main source of biomarkers, urine represents a promising alternative biological fluid. It allows a completely non-invasive sampling, high volume collection, and ease of repeated measurements; it has a lesser dynamic range, with a less complex proteome than blood.

Cancer specialist at the Queen Mary University of London (London, UK) and their colleagues obtained from multiple centers and a biomarker panel was assayed on 590 urine specimens: 183 control samples, 208 benign hepatobiliary disease samples (of which 119 were chronic pancreatitis), and 199 PDAC samples (102 stage I–II and 97 stage III–IV); 50.7% were from female individuals. PDAC samples were collected from patients before treatment. Blood and urine samples were analyzed with commercial enzyme-linked immunosorbent assay kits and the optical densities were determined using the FLUOstar Omega Microplate Reader (BMG LABTECH, Ortenberg, Germany).

The team changed their original protocol substituting Regenerating Family Member 1 Alpha (REG1A) with REG1B to enhance the performance of the panel to detect resectable PDAC. In a comparison of controls and PDAC stage I–II samples, the areas under the receiver operating characteristic curve (AUCs) increased from 0.900 and 0.926 in the training (50% of the dataset) and validation sets, respectively, to 0.936 in both the training and the validation (95% CI 0.888–0.984) datasets for the new panel including REG1B. This improved panel showed both sensitivity (SN) and specificity (SP) to be greater than 85%. Plasma CA19-9 enhanced the performance of this panel in discriminating PDAC I–II patients from controls, with AUC = 0.992, SN = 0.963, and SP = 0.967.

The authors concluded that they had successfully validated the performance of their urinary biomarker panel in detecting PDAC earlier. The PancRISK score is designed to enable further stratification of patients already predisposed to develop PDAC, thus enriching the population that should undergo follow-up, i.e., invasive clinical workup. The study was published on December 10, 2020 in the journal PLOS Medicine.





Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.