We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Diagnostic Assays Evaluated for Vitamin B12 and Folate Deficiency

By LabMedica International staff writers
Posted on 07 Dec 2020
Print article
Image: The XN-9000 Automated Hematology Analyzer (Photo courtesy of Sysmex Corporation).
Image: The XN-9000 Automated Hematology Analyzer (Photo courtesy of Sysmex Corporation).
Current guidelines pertaining to diagnosing macrocytic anemia in association with vitamin B12 and folate deficiency recommend that vitamin B12, folate, homocysteine, and methylmalonic acid assays should be assessed concurrently due to their close relationship in metabolism.

Folate is essential for the prevention of a wide spectrum of health issues, including, most notably, megaloblastic anemia and neural tube defects. Vitamin B12 is a cofactor of methionine synthase and L‐methylmalonyl–coenzyme A mutase, and the interaction between folate and vitamin B12 is responsible for the megaloblastic anemia seen in both vitamin deficiencies.

Medical Laboratorians at the Green Cross Laboratories (Yongin, Republic of Korea) retrospectively reviewed the test results from Korean adults who underwent hemoglobin (Hb) testing between September 25, 2017, and June 30, 2019, through the laboratory information system. The laboratory provides clinical specimen analysis services including serum folate, erythrocyte folate, serum homocysteine, and methylmalonic acid (i.e., serum, plasma, random urine, and 24‐hour collected urine) tests; complete blood count findings including Hb; and erythrocyte mean corpuscular volume (MCV) to clinics and hospitals nationwide.

Hb and MCV were analyzed using Sysmex XN 9000 analyzers (Sysmex Corporation, Kobe, Japan). Serum and erythrocyte folate were determined using the Elecsys Folate assay on Cobas 8000 e801 analyzers (Roche Diagnostics, Mannheim, Germany). Serum homocysteine level was determined using the AutoLab Homocysteine assay (IVD‐LAB, Uiwang-si, South Korea) on Roche Diagnostics’ Cobas 8000 c702 analyzers. Methylmalonic acid concentration in serum, plasma, random urine, and 24‐hour collected urine samples were measured using a Clarus 680 gas chromatography‐mass spectrometry analyzers (PerkinElmer, Waltham, MA, USA).

The scientists reported that during the study period, 109,524 Korean adults completed Hb tests. Among them, 14,894 (13.6%) received concurrent erythrocyte MCV tests. Among these 14,894 adults, 265 adults (107 men and 158 women; 1.2%) aged 23.9 to 95.4 years (median: 68.8 years) had macrocytic anemia, showing Hb findings below the lower limit of the reference interval for each sex and gender and MCV results of greater than 102 fL, from among 94 local clinics or hospitals without in‐house clinical laboratories. Among 265 patients with macrocytic anemia, only one woman underwent both serum vitamin B12 (464 pg/mL, reference interval: 197‐771 pg/mL) and folate (3 ng/mL, reference interval: 3.9‐26.8 ng/mL) assays. Separately, one man from a different clinic underwent serum homocysteine testing during the study period (12.0 µmol/L; upper reference limit: 15.4 µmol/L) and his results were within the reference interval.

The authors concluded that their study provided basic information regarding utilization rates of assays in association with vitamin B12 and folate deficiency. Making more data available is expected to improve rates of testing in patients with macrocytic anemia in local clinics and hospitals without in‐house clinical laboratories in Korea. The study was published on November 6, 2020 in the Journal of Clinical Laboratory Analysis.

Related Links:
Green Cross Laboratories
Sysmex Corporation
Roche Diagnostics
IVD‐LAB
PerkinElmer


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.