Fast Antibacterial Susceptibility Testing by Measuring Electron Transfer Metabolism

By LabMedica International staff writers
Posted on 07 Dec 2020
Print article
Image: A recently developed device enables faster testing of antibiotic-resistant bacteria (Photo courtesy of Dr. Seokheun `Sean` Choi)
Image: A recently developed device enables faster testing of antibiotic-resistant bacteria (Photo courtesy of Dr. Seokheun `Sean` Choi)
A recently developed device facilitates bacterial antibiotics susceptibility testing by measuring the effect of these drugs on bacterial electron transfer metabolism.

Since some 2.8 million antibiotic-resistant infections occur annually in the United States with more than 35,000 fatalities, fast and simple antimicrobial susceptibility testing (AST) is urgently required to guide effective antibiotic usages and for monitoring of the antimicrobial resistance rate.

Towards this end, investigators at Binghamton University (NY, USA) established a rapid, quantitative, and high-throughput phenotypic AST by measuring electrons transferred from the interiors of microbial cells to external electrodes. Since the transferred electrons are based on microbial metabolic activities and are inversely proportional to the concentration of potential antibiotics, the changes in electrical outputs can be readily used as a signal to efficiently monitor bacterial growth and antibiotic susceptibility.

For this study, the investigators utilized the common Gram-negative pathogenic bacterium Pseudomonas aeruginosa together with the first-line antibiotic gentamicin. The novel detector had eight sensors printed on a paper surface. The minimum inhibitory concentration (MIC) values generated by the new technique were validated by the gold standard broth microdilution (BMD) method.

Results revealed that the new approach provided quantitative, actionable MIC results within just five hours, as it measured electricity produced by bacterial metabolism instead of the days needed for growth-observation methods.

"To effectively treat the infections, we need to select the right antibiotics with the exact dose for the appropriate duration," said senior author Dr. Seokheun Choi, associate professor of electrical and computer engineering at Binghamton University. "There is a need to develop an antibiotic-susceptibility testing method and offer effective guidelines to treat these infections."

"Although many bacteria are energy-producing, some pathogens do not perform extracellular electron transfer and may not be used directly in our platform. However, various chemical compounds can assist the electron transfer from non-electricity-producing bacteria," said Dr. Choi. "For instance, E. coli cannot transfer electrons from the inside of the cell to the outside, but with the addition of some chemical compounds, they can generate electricity. Now we are working on how to make this technique general to all bacteria cells. We leverage this biochemical event for a new technique to assess the antibiotic effectiveness against bacteria without monitoring the whole bacterial growth. As far as I know, we are the first to demonstrate this technique in a rapid and high-throughput manner by using paper as a substrate."

The new method for determining bacterial antibiotic resistance was published in the November 15, 2020 issue of the journal Biosensors and Bioelectronics.

Related Links:
Binghamton University

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.