Methods for Intra-Erythrocyte Magnesium and Its Determinants Compared

By LabMedica International staff writers
Posted on 15 Oct 2020
Print article
Image Some of the components of the cobas 8000 modular analyzer series (Photo courtesy of Roche).
Image Some of the components of the cobas 8000 modular analyzer series (Photo courtesy of Roche).
Magnesium is the second most abundant intracellular cation and is essential for regulation of many functions within the cell, including modulation of ion channels, protein synthesis and energy metabolism.

Several laboratory tests to assess cellular magnesium concentrations in the human body have been evaluated, of which measurements in leukocytes generally correlate well with other magnesium pools, including skeleton, vascular smooth muscle and cardiac muscle.

Medical scientists at the University Medical Center Groningen (Groningen, the Netherlands) and their associates analyzed both urine and blood from 1,699 participants in a cohort study. The overall, mean age of the cohort was 51.0 ± 13.4 years, 57.5% were female, 36.0% were non-smoker and 11.9% non-drinker.

Plasma glucose was measured routinely on a Cobas 8000 platform (Roche, Mannheim, Germany) using a hexokinase UV test. Total cholesterol was measured using an enzymatic colorimetric assay, high-density lipoprotein cholesterol using a homogeneous enzymatic colorimetric assay, low-density lipoprotein cholesterol using a direct measurement, homogeneous enzymatic colorimetric assay, and triglycerides using a enzymatic colorimetric assay, not glycerol blanked, all measured routinely on a Cobas 8000.

The plasma magnesium concentration was also assessed using a colorimetric assay on a Cobas 8000. The colorimetric assay is based on the complex formation between magnesium ions and xylidyl blue in an alkaline solution (tris(hydroxymethyl)-aminomethane/6-aminocaproic acid buffer), forming a purple diazonium salt. EDTA whole blood samples were collected between August 2017 until December 2017. One aliquot sample was prepared for indirect intra-erythrocyte magnesium (iIEM) and one for direct intra-erythrocyte magnesium (dIEM). A validated inductively coupled plasma mass spectrometry (ICP-MS) method was used to determine magnesium in whole blood (for iIEM) and washed erythrocytes (for dIEM).

The investigators reported that the mean dIEM and iIEM were 0.20 ± 0.04 mmol/1012 cells and 0.25 ± 0.04 mmol/1012 cells, respectively. The mean plasma magnesium was 0.85 ± 0.06 mmol/L and mean urinary magnesium excretion was 4.85 ± 1.76 mmol/24-h. They found a strong correlation between dIEM and iIEM. Passing-Bablok regression analyses showed an intercept of 0.015 (95% CI: 0.005; 0.023) and a slope of 1.157 (95% CI: 1.109; 1.210). In linear regression analyses, plasma levels of total- and LDL -cholesterol, and triglycerides were positively associated dIEM, iIEM, and plasma magnesium, while glucose and HbA1c were inversely associated with plasma magnesium.

The authors concluded that there was a strong correlation between a direct and an indirect method for the assessment of IEM. The study indicated that iIEM can be used in practice, eliminating labor-intensive washing procedures and high costs required for direct methods. The study was published on September 11, 2020 in the journal Clinica Chimica Acta.




Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.