Mannose-Binding Lectin Associated with Coagulopathy in Severe COVID-19

By LabMedica International staff writers
Posted on 24 Sep 2020
Print article
The ongoing COVID-19 pandemic has caused significant morbidity and mortality worldwide, as well as profound effects on society. COVID-19 patients have an increased risk of thromboembolic (TE) complications, which develop despite pharmacological thromboprophylaxis.

The mechanism behind COVID-19-associated coagulopathy remains unclear. Mannose-binding lectin (MBL), a pattern recognition molecule that initiates the lectin pathway of complement activation, has been suggested as a potential amplifier of blood coagulation during thromboinflammation.

Immunologists at the Uppsala University (Uppsala, Sweden) and their colleagues clarify the role of MBL in COVID-19 and measured plasma MBL levels and activity in a cohort of 65 critically ill COVID-19 patients and investigated its relation to clinical outcome. All patients were over 18 years of age with confirmed or suspected COVID-19 admitted to the ICU between March 13 and April 30, 2020, were screened for inclusion.

Blood was sampled in ethylenediaminetetraacetic acid tubes, and plasma stored at –70 °C until analysis. Plasma MBL levels at day 1 at the ICU (on average COVID-19 day 10) were measured by an in-house enzyme-linked immunosorbent assay (ELISA), and were significantly higher than in healthy controls. Activity of the MBL pathway was assessed by a functional ELISA using mannan as activator and MBL binding capacity and complement C3 deposition as readouts. This assay measures the functional MBL concentration in plasma and its capacity to activate complement, and confirmed elevated MBL activity and MBL-dependent C3 deposition in the patient group.

The team reported that nine (14%) patients who developed symptomatic thromboembolism, despite receiving thromboprophylaxis, had significantly higher MBL levels than patients who did not experience a thromboembolic event (median 1,233 kU/L versus 470 kU/L). All patients in the study received thromboprophylaxis with either dalteparin sodium (n = 64) or apixaban (n = 1). Of the nine patients in the study who developed a symptomatic thromboembolic event during their time at the ICU, two were arterial thrombosis (stroke or myocardial infarction) and seven were pulmonary embolisms (PEs). COVID-19 patients have elevated plasma MBL levels compared with healthy controls: 625 kU/L in the patient group (n = 65) versus. 444 kU/L in the healthy blood donors controls (n = 72).

Interestingly, patients who developed PE all had MBL levels above the 95th percentile compared with controls. MBL showed a significant correlation with total complement factor C3 levels, but not with the activation product C3d (measured as C3d/C3 ratio), a measure of activity of the alternative pathway of complement, nor with C1q, the initiator of the classical pathway. Total C3 levels, C3d/C3 ratio, or C1q were not related to thrombotic events, indicating a specific association between MBL and thrombosis.

The authors concluded that they had identified complement activation through the MBL pathway as a novel amplification mechanism that contributes to pathological thrombosis in critically ill COVID-19 patients. Pharmacological targeting of the MBL pathway could be a novel treatment option for thrombosis in COVID-19. Laboratory testing of MBL levels could be of value for identifying COVID-19 patients at risk for thromboembolic events. The study was published on September 1 2020 in the journal Thrombosis and Haemostasis.

Related Links:
Uppsala University

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.