Quantitative Agglutination Determined on Automatic Hematology Analyzer

By LabMedica International staff writers
Posted on 16 Sep 2020
Print article
Image: The Mindray BC-2800 Fully Automatic Hematology Analyzer with 19 Parameters for CBC /Blood Cell Test for Hospital Use (Photo courtesy of Mindray).
Image: The Mindray BC-2800 Fully Automatic Hematology Analyzer with 19 Parameters for CBC /Blood Cell Test for Hospital Use (Photo courtesy of Mindray).
The currently available agglutination identification methods are slide methods and test tube methods. Based on the distribution, uniformity and comprehensive changes of non-aggregated cells and agglutinating cells in the liquid, the agglutination degree and strength can be determined by the naked eye.

The results are subject to the subjective influence of the observers, and it has been shown that the amount of agglutination determined in the same sample by different people and the determination of the same sample by the same person at different times were significantly different, thus affecting the accuracy and reliability of the study.

Medical Laboratorians at the Dalian Medical University (Dalian, China) selected and diluted Type A serum to react with the type B cells and the normal saline group was used as the control group. A red blood cell (RBC) count was performed using an automatic hematology analyzer (Mindray, Shenzhen, China), after incubation in a warm bath for 30 minutes. The degree of agglutination on the glass slide was also recorded. A positive serum of antinuclear antibody (ANA) was collected and RBC agglutination between RBC-O and ANA positive serum was determined using the automatic hematology analyzer method.

The scientists reported that the relationship between the results from the automatic hematology analyzer and the agglutination strength using the glass slide method was determined and showed that there was a good linear relationship between the agglutination index (AGI) and serum antibody concentration. There was a significant difference between the serum of ANA positive patients and the normal control group. The stability test results showed a coefficient of variation (CV) < 10% when using the automatic hematology analyzer, indicating that the reproducibility of the test was good.

The investigators found that when normal human serum (control group) was mixed with red blood cells the value was lower than when mixed with normal saline (AGI). Furthermore, the analysis found that the AGI value was normally distributed, so they believe that healthy donors are likely to have a low level of resistance to RBC antibody. This shows that the automatic hematology analyzer can detect weak agglutination antibody in serum, but classical methods cannot observe this phenomenon.

The authors concluded that the automatic hematology analyzer can not only effectively detect the agglutination antibody in serum, but also provides a new tool for clinical application to detect agglutination with high sensitivity, and is quantitative, objective and accurate. The study has been available online since July 3, 2020 in the journal Clinica Chimica Acta.


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The real-time multiplex PCR test is set to revolutionize early sepsis detection (Photo courtesy of Shutterstock)

1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens

Sepsis contributes to one in every three hospital deaths in the US, and globally, septic shock carries a mortality rate of 30-40%. Diagnosing sepsis early is challenging due to its non-specific symptoms... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.