We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Serological Dipstick Assay Developed for Melioidosis

By LabMedica International staff writers
Posted on 05 Aug 2020
Print article
Image: The Melioidosis DS assay principle: A dipstick is placed into a well containing patient serum diluted in dipstick master mix (running buffer, detection antibody and control reagent) (Photo courtesy of Medical University of Graz).
Image: The Melioidosis DS assay principle: A dipstick is placed into a well containing patient serum diluted in dipstick master mix (running buffer, detection antibody and control reagent) (Photo courtesy of Medical University of Graz).
The Gram-negative environmental pathogen Burkholderia pseudomallei, causes the severe disease melioidosis. It is highly endemic in southeast Asia and northern Australia, but recent studies suggest that it is also present in many other parts of the world where it is severely underreported.

The underreporting results from the extremely variable and non-specific clinical manifestations of the disease, lack of clinical recognition, and the global scarcity of good quality laboratories to allow diagnosis from microbiological culture. Early diagnosis of the disease is indispensable for an effective therapy, since B. pseudomallei is intrinsically resistant to many antibiotics used for empirical treatment in endemic areas.

Medical microbiologists at the Medical University of Graz (Graz, Austria) and their international colleagues developed a dipstick assay, which was based on the detection of serum antibodies against four B. pseudomallei specific protein antigens. They evaluated their Melioidosis DS rapid test by using the same set of human serum samples that were previously characterized. The serum collection consisted of 75 sera from culture-confirmed melioidosis patients upon admission and 100 healthy controls. They also tested another 95 samples from Thailand on their dipsticks. These sera were previously classified as 55 false-negative or 40 false-positive on a heme carrier protein 1 (Hcp1) based lateral flow assay. Twenty-eight of the false-positive sera were drawn from healthy individuals and 12 from patients suffering from other kinds of infections.

The investigators reported that their 4-plex dipstick was validated with sera from 75 patients on admission plus control groups, achieving 92% sensitivity and 97% to 100% specificity. They then re-evaluated melioidosis sera with the 4-plex assay that were previously misclassified by the monoplex Hcp1 rapid test. They found that 12/55 (21.8%) false-negative samples were positive in the new dipstick assay. Among those, four sera (7.3%) were Hcp1 positive, whereas eight (14.5%) sera remained Hcp1 negative but gave a positive reaction with their additional antigens.

The authors concluded that the dipstick rapid test represents an inexpensive, standardized and simple diagnostic tool with an improved serodiagnostic performance due to multiplex detection. Each additional band on the test strip makes a false-positive result more unlikely, contributing to its reliability. The study was published on July 13, 2020 in the journal PLOS Neglected Tropical Diseases.

Related Links:
Medical University of Graz

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.