We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

SYSMEX-EUROPA

Sysmex Europe designs and produces laboratory and hematology diagnostic solutions, including instruments, reagents, c... read more Featured Products: More products

Download Mobile App




Lupus Anticoagulant Prolongs Activated Partial-Thromboplastin Time in COVID-19

By LabMedica International staff writers
Posted on 20 May 2020
Print article
Image: The CS-2400 is a high performance coagulation station that allows laboratories to perform routine and specialized testing including platelet function tests (Photo courtesy of Sysmex).
Image: The CS-2400 is a high performance coagulation station that allows laboratories to perform routine and specialized testing including platelet function tests (Photo courtesy of Sysmex).
Patients with coronavirus disease 2019 (COVID-19) have a profound hypercoagulable state, and complicating venous thrombotic events are common. Abnormalities in coagulation screening measures, including a prolonged activated partial-thromboplastin time (aPTT), have been reported in patients with COVID-19.

A prolonged aPTT may indicate a clotting-factor deficiency or the presence of an inhibitor of coagulation that is either specific such as antibody to factor VIII or nonspecific such as lupus anticoagulant. Lupus anticoagulant can affect in vitro tests of blood coagulation, but typically is not associated with bleeding. As part of the antiphospholipid syndrome, lupus anticoagulant is associated with a thrombotic risk.

A team of Medical Scientists at the Royal London Hospital (London UK) and their associates investigated the cause of prolonged aPTT in 35 patients (median age, 57 years; 24 were male) with COVID-19 who were treated at the hospital. At the time of sampling, 21 patients were tested while in critical care, 10 were from in-patients or Emergency Department (ED) patients were admitted for >24 hours, and four were from ED patients who were discharged within 24 hours. Pulmonary embolism was confirmed in one patient, and clinically suspected thrombosis was present in one patient.

None of the patients had deficiencies in factor VIII or factor IX. In five patients, marginal reductions in factor XI were found that were unlikely to be of clinical significance. The factor XII level was ≤50 IU/dL in 16 patients. Coagulation assays were performed on Sysmex CS-series analyzers (Sysmex Corporation, Kobe, Japan). Lupus anticoagulant (LA) screening assays were performed using Siemens LA1 reagent for dilute Russell’s Viper Venom Time (DRVVT, Siemens Healthineers, Erlangen, Germany), and Diagnostica Stago PTT-LA reagent (Diagnostica Stago, Reading, UK) for APTT.

Lupus anticoagulant assays were performed in 34 patients, and 31 (91%) were positive. The presence of lupus anticoagulant was indicated by two assays in 18 of the 34 (53%) patients, by DRVVT alone in seven (21%), and by lupus anticoagulant-sensitive aPTT alone in six (18%). All samples that were positive for lupus anticoagulant had a prolonged aPTT with a 50:50 mix (sample made up of 50% patient plasma and 50% normal plasma).

In a historical control cohort of 540 specimens received for lupus anticoagulant testing, 43 (8%) had an aPTT of ≥30 seconds, and 11 of the 43 (26%) were positive for lupus anticoagulant. The percentage of specimens that were positive for lupus anticoagulant was significantly higher among the patients with COVID-19 than in the control cohort.

The authors suggested that a prolonged aPTT should not be a barrier to the use of anticoagulation therapies in the prevention and treatment of venous thrombosis in patients with COVID-19. In their opinion, clinicians should not withhold use of anticoagulants for thrombosis while awaiting further investigation of a prolonged aPTT, nor should they withhold thrombolytic therapy in the face of a high-risk pulmonary embolism on the basis of a prolonged aPTT alone. The study was published on May 5, 2020 in The New England Journal of Medicine.


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.