We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Deep Throat SARS-CoV-2 Viral Load Ascertained in Saliva Samples

By LabMedica International staff writers
Posted on 06 Apr 2020
Print article
Image: The Oxford Nanopore MinION device (Photo courtesy of Oxford Nanopore Technologies).
Image: The Oxford Nanopore MinION device (Photo courtesy of Oxford Nanopore Technologies).
Posterior oropharyngeal saliva samples are a non-invasive specimen more acceptable to patients and health-care workers. Unlike severe acute respiratory syndrome, patients with COVID-19 had the highest viral load near presentation, which could account for the fast-spreading nature of this epidemic.

In most studies of respiratory virus infections, serial sampling of nasopharyngeal or throat swabs is used for viral load monitoring. However, collection of nasopharyngeal or throat swab specimens can induce coughing and sneezing, which generates aerosol and is a potential health hazard for health-care workers.

Scientists at the University of Hong Kong (Pokfulam, Hong Kong Special Administrative Region, China) and their colleagues carried out a cohort study at two hospitals in Hong Kong between January 22, 2020, and February 12, 2020. They included patients with laboratory-confirmed COVID-19. They obtained samples of blood, urine, posterior oropharyngeal saliva, and rectal swabs. Serial viral load was ascertained by reverse transcriptase quantitative PCR (RT-qPCR). Antibody levels against the SARS-CoV-2 internal nucleoprotein (NP) and surface spike protein receptor binding domain (RBD) were measured using an enzyme immune assay (EIA). Whole-genome sequencing was done to identify possible mutations arising during infection using the Oxford Nanopore MinION device (Oxford Nanopore Technologies, Oxford, UK).

The team reported that the median viral load in posterior oropharyngeal saliva or other respiratory specimens at presentation was 5.2 log10 copies per mL. Salivary viral load was highest during the first week after symptom onset and subsequently declined with time. In one patient, viral RNA was detected 25 days after symptom onset. For 16 patients with serum samples available 14 days or longer after symptom onset, rates of seropositivity were 94% for anti-NP IgG (n = 15), 88% for anti-NP IgM (n = 14), 100% for anti- surface spike protein receptor binding domain (RBD) IgG (n = 16), and 94% for anti-RBD IgM (n = 15). Anti-SARS-CoV-2-NP or anti-SARS-CoV-2-RBD IgG levels correlated with virus neutralization titer.

The authors concluded that COVID-19 is an emerging infection with many unknowns. Their study has shed light on viral kinetics and antibody response in patients and provides scientific evidence for guiding infection control policies and therapeutics. The study was published on March 23, 2020 in the journal The Lancet Infectious Diseases.

Related Links:
University of Hong Kong
Oxford Nanopore Technologies


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.