We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




D‐dimer Levels Predict Ischemic Stroke in Infective Endocarditis

By LabMedica International staff writers
Posted on 17 Feb 2020
Print article
Image: Blood test for D-dimer showed high sensitivity and specificity in the prediction of ischemic stroke in patients with infective endocarditis (Photo courtesy of Blue Horizon).
Image: Blood test for D-dimer showed high sensitivity and specificity in the prediction of ischemic stroke in patients with infective endocarditis (Photo courtesy of Blue Horizon).
Infective endocarditis (IE) is a life‐threatening disease, especially in developing countries. IE may present many extra‐cardiac symptoms or signs, in which neurological complications are the most prominent and severe.

The manifestations of these neurological complications include ischemic stroke, hemorrhagic stroke, mycotic aneurysms, brain abscesses, meningitis, and encephalitis. Ischemic stroke, characterized by the interruption of cerebral blood flow, is a dominant and frequent neurological complication of left‐sided IE, as well as the main stroke type among all stroke cases in IE.

Infectious disease specialists at the Tianjin Medical University General Hospital (Tianjin, China) enrolled in a prospective study, a total of 173 consecutive patients with IE from January 2016 to December 2018. All patients were hospitalized for the first time with a definite diagnosis of IE based on the modified Duke criteria. The primary diagnosis of ischemic stroke was mainly based on clinical neurological symptoms and imaging manifestations on brain magnetic resonance imaging (MRI).

The team performed the measurement of plasma D‐dimer on admission using the VIDAS D‐dimer assay (bioMérieux, Marcy-l'Étoile, France), which has shown comparable sensitivity and specificity. The normal range of plasma D‐dimer is 0‐500 μg/L. Other hematological and biochemical data, such as white blood cell (WBC) count and C‐reactive protein (CRP), were also detected from peripheral blood samples collected on the next morning after admission. In addition, to identify causative organisms, at least three sets of blood cultures were obtained from all patients before the initiation of antibiotic therapy.

The scientists reported that ischemic stroke was observed in 38 (22%) patients during 6‐month follow‐up since definite diagnosis of IE. Patients with ischemic stroke had significantly higher levels of plasma D‐dimer than those of patients without stroke (4,982 versus 2,205 μg/L). Positive results of blood cultures were obtained from 107 (62%) patients. Streptococcus identified in 40 (23%) patients was the most common microorganism, accounting for 37% of all positive blood cultures. The secondary dominant causative agent was Staphylococcus aureus, isolated in 33 (19%) patients and 31% of all positive blood cultures.

In addition, Staphylococcus aureus infection (Hazard Ratio (HR): 1.96), mitral valve vegetation (HR: 1.52), and higher levels of on‐admission plasma D‐dimer (HR: 1.35) were significantly associated with ischemic stroke. Moreover, D‐dimer levels ≥3,393 μg/L served as a strong predictor for ischemic stroke in patients with IE, and the sensitivity and specificity were 78% and 83%, respectively.

The authors concluded that their study revealed that higher levels of on‐admission plasma D‐dimer showed high sensitivity and specificity in the prediction of ischemic stroke, which occurred mostly in the first three months after the diagnosis of IE. On the one hand, as a traditional and inexpensive biomarker, plasma D‐dimer may help clinicians identify high‐risk IE patients for ischemic stroke in a simple and quick way. The study was published on February 3, 2020 in the Journal of Clinical Laboratory Analysis.

Related Links:
Tianjin Medical University General Hospital
bioMérieux


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.