We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

THERMO FISHER SCIENTIFIC

Thermo Fisher Scientific provides analytical instruments, lab equipment, specialty diagnostics, reagents and integrat... read more Featured Products: More products

Download Mobile App




Diagnostic Assay Identifies Leukemic Stem Cells

By LabMedica International staff writers
Posted on 15 Jan 2020
Print article
Image: The Attune NxT Acoustic Focusing Cytometer is ideal for immunophenotyping and signaling studies, cell cycle analysis, detection of rare events, stem cell analysis, cancer and apoptosis studies, microbiological assays, and more (Photo courtesy of Thermo Fisher Scientific)
Image: The Attune NxT Acoustic Focusing Cytometer is ideal for immunophenotyping and signaling studies, cell cycle analysis, detection of rare events, stem cell analysis, cancer and apoptosis studies, microbiological assays, and more (Photo courtesy of Thermo Fisher Scientific)
Acute myeloid leukemia (AML) is the most common type of leukemia in adults. It is characterized by the pathological expansion of immature cells (myeloblasts) that invade the bone marrow and expand into the blood, affecting the production of the rest of the healthy cells.

Although AML patients usually respond well to chemotherapy-based treatments, large proportion of them eventually relapse or show resistance to these procedures. The cause of relapse or resistance to treatment is sometimes due to the existence of leukemic stem cells capable of starting cancer again, and in turn, for being resistant to chemotherapy. However, identifying them is a challenge since there are no specific markers to detect and isolate them.

Scientists at the Josep Carreras Leukaemia Research Institute (Badalona, Spain) and their colleagues carried out a prospective hospital-based cohort study that included 43 newly diagnosed patients with acute myeloid leukemia. There were 30 males, and 13 females; with a median age of 63 years, (range 26–91) in the study cohort. A total of 12 out of 43 patients underwent allogeneic stem cell transplant (ASCT) following chemotherapy.

The team used flow cytometric cellular alkaline phosphatase (ALP) activity within primitive leukemic cells which allowed them to identify two groups of patients at diagnosis according to the numbers of leukemic blasts expressing ≥ 12% of ALP+ cells (27 patients, Group A) and less than 12% of ALP+ cells (16 patients, Group B). All 38 EDTA-anticoagulated bone marrow and five blood samples were prepared using a modified previously developed method aimed at avoiding the lysis of erythrocytes during sample preparation, which can result in unwanted damage to leukocytes, and conceivably to leukemic cells.

DNA content cell cycle and stem cell Side Population analysis was accomplished by flow cytometry. Stained cells were diluted with Hank’s Balanced Salt Solution (HBSS) (1,000 µL final volume) prior to sample acquisition. All cell measurements were done using the Attune Acoustic Focusing Cytometer and the Attune NxT Acoustic Focusing Cytometer (Thermo Fisher Scientific, Eugene, OR, USA).

The scientists reported that differences in outcome for complete response, relapse or treatment resistance, and exitus were statistically analyzed and were significant, when comparing the two groups. The overall survival (OS) and event-free survival (EFS) differences between Group A and B were statistically significant. The survival of Group A patients was significantly shorter than those for Group B. The AML patients had a median value of 18.33% ALP+ blast cells (range 0.26–96.93). Twenty-seven patients in Group A had a median value of 23.76% of ALP+ blast cells ranging from 13.83 to 96.63), and 16 patients in Group B had a median value of 4.99% of ALP+ blast cells ranging from 0.26 to 11.98.

The authors concluded that flow cytometric cellular ALP activity at diagnosis may be used to estimate relapses and disease persistence more accurately. The limitations of the study include the small number of patients enrolled and a short follow-up, due to its prospective nature. The study was published on December 10, 2019 in the journal Oncotarget.

Related Links:
Josep Carreras Leukaemia Research Institute
Thermo Fisher Scientific


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.