Value and Use of Urinalysis for Myoglobinuria

By LabMedica International staff writers
Posted on 16 Dec 2019
Print article
Image: Urine from a person with rhabdomyolysis showing the characteristic brown discoloration as a result of myoglobinuria (Photo courtesy of James Heilman, MD).
Image: Urine from a person with rhabdomyolysis showing the characteristic brown discoloration as a result of myoglobinuria (Photo courtesy of James Heilman, MD).
Rhabdomyolysis is a syndrome involving acute muscle injury caused by numerous conditions, such as trauma), intense exercise, inflammatory or hereditary myopathies, snake toxins, seizures, alcohol or drug overdose, hyperthermia, and severe hypokalemia.

Muscle damage leads to increased serum levels of creatine phosphokinase and myoglobin, which serve as primary indicators for laboratory diagnosis. Measurements of peak levels and clearance rates of serum myoglobin have been reported to have value for predicting acute renal failure in patients with rhabdomyolysis. Its detection in urine may also serve as an aid in diagnosis and assessment of severe rhabdomyolysis, and secondarily as a biomarker for risk of renal injury.

Medical Laboratory Professionals at the Southern Arizona VA Healthcare System (Tucson, AZ, USA) conducted a retrospective observational study involving all identifiable urine myoglobin results as well as blood and microscopic red blood cell results by urinalysis. Other than general myoglobin testing method (qualitative or quantitative) no other information was available. No patient demographics or clinical information was obtained. Urine myoglobin concentrations 1,000 μg/L or greater were considered clinically significant for potential renal toxicity. Hematuria was defined as five or more red blood cells/µL

The team reported that a total of 13,139 urine myoglobin results from 88 Veterans Affairs facilities during a 15-year period ending in October 2014 were evaluated. Among methods used by each laboratory, qualitative urine myoglobin tests declined from 25 of 53 (47.1%) in 2000 to 5 of 77 (6.4%) in 2013. Of 7,311 tests (55.6%) performed by quantitative methods with concomitant urinalysis, 3.915 (53.5%) showed negative to trace blood results, of which myoglobin was 1,000 μg/L or greater in 17 (0.4%). Among 1,875 (25.5%) with 3+ (large) blood results, urine myoglobin was ≥1,000 μg/L in 273 of 1,533 (17.8%) with hematuria (≥5 red blood cells per microliter) and 109 of 342 (31.9%) without hematuria.

The authors concluded that their study provided evidence-based support for the role of urinalysis in testing for myoglobinuria. Measurement of urine myoglobin is unnecessary in cases with absent or only small amounts of blood by urinalysis which reliably excludes the presence of clinically significant myoglobinuria. Conversely, the presence of increasing amounts of blood by urinalysis progressively raises the probability of myoglobinuria, especially in the absence of hematuria. When urine myoglobin cannot be promptly and accurately measured, its value is limited to that of a confirmatory test, with marginal clinical impact when used for diagnosis and management of rhabdomyolysis compared to that provided by urinalysis results. The study was published in the November, 2019 issue of the journal Archives of Pathology & Laboratory Medicine.

Related Links:
Southern Arizona VA Healthcare System

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.