We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Fluorimetric Assay Quantifies Galactocerebrosidase Activity in Dried Blood Spots

By LabMedica International staff writers
Posted on 29 Oct 2019
Print article
Image: The Synergy HTX multi-mode microplate reader is a compact, affordable system for 6- to 384-well microplates and Take3 Micro-Volume Plates (Photo courtesy of BioTek).
Image: The Synergy HTX multi-mode microplate reader is a compact, affordable system for 6- to 384-well microplates and Take3 Micro-Volume Plates (Photo courtesy of BioTek).
The lysosomal enzyme galactocerebrosidase hydrolyzes glycosidic bonds of several glycosphingolipids, including galactose from galactosylsphingosine (psychosine), and is essential to prevent the toxic accumulation of psychosine in the body.

Decreased galactocerebrosidase (GALC) enzyme activity is causative for Krabbe disease, a lysosomal storage disorder with devastating neurodegenerative consequences. Quantitative fluorimetric assays for GALC activity in isolated blood and skin cells have been described, but not for dried blood spots specimens (DBS).

A team of scientists from the commercial company Baebies, Inc (Durham, NC, USA) and Duke University (Durham, NC, USA) developed a rapid, microtiter plate fluorimetric assay for measuring GALC enzyme activity in DBS specimens using a novel substrate: β-galactose conjugated with a fluorogenic derivative of 6-hexadecanoyl-4-methylumbelliferone with a hydrophobic group.

Samples were obtained as individual punches (3.2 mm diameter) from DBS cards of presumed normal newborns. Archived, deidentified DBS from 10 affected Krabbe disease patients were obtained from the Legacy of Angels Foundation. To extract galactocerebrosidase enzyme from the DBS samples, one punch (3.2 mm) from each DBS was placed in individual wells of a clear, round-bottom, 96-well microtiter plate.

Sample extraction solution (100 μL) was added to each sample well; the plate was covered with a clear adhesive sealer to prevent evaporation and then incubated on a plate-shaker (600 rpm) at room temperature (RT) for 30 minutes. Enzyme activity was determined by adding 10 μL of DBS extract to 10 μL of the GALC substrate solution, which was varied. The fluorescence of the plate, measured as relative fluorescence units (RFU), was read in a Synergy HTX microtiter plate reader with 400 ±15 nm excitation and 485 ±20 nm emission filters.

The GALC assay was carefully optimized to ensure robust performance from the small amount of enzyme present in DBS and to minimize interference from β-galactosidase. The team found that the linear range of the fluorimetric GALC assay encompassed the entire range of samples tested. The activity in the presumed normal samples shows a wide range (0.39 – 15.6 μmol/L/hour) with a population mean of 2.108 μmol/L/hour. As expected, GALC activity in the affected samples is significantly lower than in the presumed normal samples.

The authors concluded that a fluorimetric assay for GALC enzyme activity measurement on dried blood spot specimens is feasible. Improvements to the assay including novel substrate design, increased substrate concentration and removal of sodium chloride maximize the specificity of the assay and minimize interference from β-galactosidase. The study was published on October 16, 2019, in the journal Practical Laboratory Medicine.

Related Links:
Baebies
Duke University

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: The new method could reduce undiagnosed cancer cases in less-developed regions (Photo courtesy of 123RF)

New Method Offers Sustainable Approach to Universal Metabolic Cancer Diagnosis

Globally, more than one billion people suffer from a high rate of missed disease diagnosis, highlighting the urgent need for more precise and affordable diagnostic tools. Such tools are especially crucial... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.