We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

HORIBA Medical

HORIBA ABX designs, develops and distributes worldwide, in vitro diagnostic systems for biological analysis in medica... read more Featured Products: More products

Download Mobile App




Events

09 Apr 2024 - 12 Apr 2024
15 Apr 2024 - 17 Apr 2024
23 Apr 2024 - 26 Apr 2024

Human CRP-Levels Compared Using Point-of-Care Methods

By LabMedica International staff writers
Posted on 08 Oct 2019
Print article
Image: The ABX Micros CRP 200 hematology analyzer (Photo courtesy of Horiba Medical).
Image: The ABX Micros CRP 200 hematology analyzer (Photo courtesy of Horiba Medical).
Due to the rapid increase of the C-reactive protein (CRP) concentration in the event of an inflammatory disease, CRP is regarded as one of the most important acute phase proteins. Inflammation and CRP play an important role in operations, trauma, mental stress, myocardial infarction and neoplastic diseases.

The use of point-of-care (POC) methods and the measurements of CRP as a diagnostic marker have both increased over the past years. This has led to an increase in POC-methods analyzing CRP. High CRP levels are often seen as an indication for the proscribing of antibiotics. The quality of POC-systems compared to routine diagnostic measurements for the analysis of CRP is thereby of major importance, since many small practices will use POC-methods.

Biomedical scientists from the Salzburg University of Applied Sciences (Puch bei Hallein, Austria) compared POC and classical clinical chemistry methods, using 199 anonymized patient samples (104 male and 95 female patients aged from 31 to 96 years). The blood samples were selected based on a CRP concentration of more than 100 mg/L as measured by the Architect ci8200SR.

Comparisons were then made with ABX Micros CRP 200 (Horiba, Kyoto, Japan) and the i-CHROMA system. The CRP-levels on the Architect ci8200 were detected using serum samples and the method is based on a turbidimetric assay. EDTA-whole blood was used for the test procedure with the i-CHROMA and ABX. The ABX also works with a turbidimetric assay system and the i-CHROMA is based on a fluorescence sandwich immunoassay. The values from the i-CHROMA were used corrected for the hematocrit values.

The scientists reported that the results of the Architect ci8200 and the ABX showed significant differences when compared to the results of the i-CHROMA with hematocrit corrections. In addition, the values of the Architect ci8200 and the ABXs were also significantly different. Nevertheless, the most pronounced differences were seen when comparing the i-CHROMA with the Architect ci8200 with detected differences of up to 147.6 mg/L. Comparing the values of the i-CHROMA with the ABX resulted in differences of up to 92.7 mg/L. The lowest maximal difference of 39.4 mg/L is seen when comparing the results of the Architect ci8200 and the ABX.

The authors concluded that the measured CRP concentrations of the i-CHROMA strongly differ in the higher CRP concentration range when compared to the measurements performed on routine diagnostic equipment. The significantly reduced CRP measurements can strongly affect patient safety and result in wrong diagnostic measures. The study was published on September 19, 2019, in the journal Practical Laboratory Medicine.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
HLX
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Molecular Diagnostics

view channel
Image: The cobas Malaria test is the first FDA-approved molecular test to screen U.S. blood donors for malaria (Photo courtesy of Roche)

First FDA-Approved Molecular Test to Screen Blood Donors for Malaria Could Improve Patient Safety

Malaria, a serious illness that often leads to death, is spread by a specific mosquito species that infect humans with a parasite. Other transmission modes include blood transfusions, organ transplants,... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The medical office procedure detects the key biomarker in Parkinson’s and related neurodegenerative diseases (Photo courtesy of BIDMC)

Simple Skin Biopsy Test Detects Parkinson’s and Related Neurodegenerative Diseases

Parkinson's disease and a group of related neurodegenerative disorders known as synucleinopathies impact millions globally. These conditions, including Parkinson’s disease (PD), dementia with Lewy bodies... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.