We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Biomarkers Panel Used for Pleural and Peritoneal Effusions Diagnosis

By LabMedica International staff writers
Posted on 25 Sep 2019
Print article
Image: The MAGPIX fluorescent-based analytical instrument (Photo courtesy of Luminex).
Image: The MAGPIX fluorescent-based analytical instrument (Photo courtesy of Luminex).
The quantification of biomarkers in cavity fluids may aid in the etiological diagnosis and in patients' management. Laboratory investigation of cavity effusions involves the evaluation of biochemical, immunological, microbiological, molecular and cellular parameters.

The broad spectrum of etiologic causes of pleural effusion (PE) and peritoneal effusion (PerE) justifies studies with biomarkers quantified in samples obtained through thoracentesis and/or paracentesis, procedures considered minimally invasive and at a low risk for patients.

Scientists at the University of Sao Paulo (San Paulo, Brazil) evaluated Samples of pleural or peritoneal fluid from 120 patients submitted to thoracentesis or paracentesis for diagnostic investigation. Each sample was representative of one patient. The team evaluated the following biomarkers: carcinoembryonic antigen (CEA), vascular endothelial growth factor A (VEGF-A) programmed death-ligand 1 (PD-L1/B7-H1), neutrophil gelatinase-associated lipocalin (NGAL), triggering receptor expressed in myeloid cells type-1(TREM-1), and gamma-interferon (IFNγ).

Samples of PE or PerE were prepared for analysis in a 96-well plate utilizing a custom Luminex Human Magnetic Assay. CEA, VEGF-A, PD-L1, NGAL, TREM-1 and IFNγ were quantified using a MAGPIX analytical test instrument. The concentrations of Calprotectin were obtained by a ‘sandwich’ ELISA test with CALP human kit and analyzed on Victor X3 plate reader in a 450 nm low-pass absorbance. The assay used for adenosine desaminase (ADA) was the Quimiada Adenosina Deaminase kit, and a concentration above 30 U/L is presumptive of tuberculosis.

The team reported that for malignant effusion (ME) diagnosis, CEA and NGAL presented superior performance than VEGF-A, PD-L1 and CALP. A CEA-NGAL association showed good sensitivity (86.6%) and accuracy (79.2%). For non-tuberculous infectious effusion (NTBIE), NGAL presented the best performance with sensitivity (75.0%), specificity (62.0%) and accuracy (65.0%) higher than TREM-1 and CALP; however, when associated, although with good sensitivity, there was important decrease in specificity. For tuberculous pleural effusion (TPE), IFNγ-ADA presented excellent sensitivity (100%), specificity (87.6%), NPV (100%) and accuracies (~90%).

The authors concluded that a hybrid panel composed by the biomarkers CEA, NGAL, IFNγ and ADA seems to be useful in discriminating between ME and TPE etiology, both lymphocytic effusions. For non-tuberculous infectious effusion, the panel used did not demonstrate diagnostic advantages over the classic literature parameters. The study was published in the October 2019 issue of the journal Clinica Chimica Acta.

Related Links:
University of Sao Paulo

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Molecular Diagnostics

view channel
Image: Liquid biopsy could detect and monitor aggressive small cell lung cancer (Photo courtesy of Shutterstock)

Blood-Based Test Detects and Monitors Aggressive Small Cell Lung Cancer

Small cell lung cancer (SCLC) is a highly aggressive type of cancer known for its ability to metastasize. The behavior of tumors is largely governed by which genes are turned on, or transcribed, irrespective... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.